EN 115
3139 785 31532
5.
Firmware Upgrading & Diagnostic Software
5.4
DVD Module Error code
With DSW command 910 the set software can retrieve an
overview of all occurred engine errors.
5.4.1
Momentary Errors
Byte 0: latest error:
Overview of the BE error codes.
error
code
error
meaning
0x00
no_error
No error has occurred
0x01
illegal_command_error
Command not allowed in this
state or unknown command
0x02
illegal_parameter_error
Parameter(s) not valid for this
command
0x03
command_timeout_error
The maximum execution time for
the command has exceeded
0x04
sledge_home_error
The sledge could not be moved
home
0x05
sledge_calibration_error
An error occurred during calibra-
tion of the sledge
0x06
sledge_unstable_error
The sledge detected unstable
control
0x07
speed_timeout_error
Spindle motor could not reach its
target speed within timeout
0x08
speed_window_error
Measured spinning speed is not
within expected window
0x09
focus_timeout_error
Focus could not be achieved
within the timeout
0x0A
focus_retries_error
The amount of focus retries ex-
pired
0x0B
focus_agc_error
The focus agc results are out of
range
0x0C
radial_timeout_error
Servo didn’t get on track within
the timeout
0x0D
radial_retries_error
Servo didn’t get on track after
several retries
0x0E
radial_agc_error
The radial agc results are out of
range
0x0F
radial_init_error
Unreliable signal scaling after the
radial initialisation
0x10
hf_pll_error
HF-decoder pll could not lock to
HF signal
0x11
wobble_pll_error
Wobble pll could not lock to wob-
ble signal
0x12
subcode_timeout_error
Subcode information could not
be read
0x13
subcode_notfound_error
Requested subcode item could
not be found
0x14
header_timeout_error
Header information could not be
read
0x15
adip_timeout_error
Adip information could not be
read
0x16
adip_window_error
Adip address was not within ex-
pected window
0x17
adip_sync_error
No adip sync was detected
0x18
atip_timeout_error
Atip information could not be
read
0x19
atip_notfound_error
Requested atip item could not be
found
0x1A
atip_window_error
Atip address was not within ex-
pected window
0x1B
atip_sync_error
No atip sync was detected
0x1C
tray_error
Tray could not be closed or
opened within the timeout
0x1D
seek_error
The requested seek couldn’t be
performed within the timeout
0x1E
no_hf_present_error
Attempt to read from a blank area
0x1F
record_error
An error occurred during the re-
cording
0x20
illegal_stopaddress_error
The requested stopaddress with
modify-stop-address is not valid
0x21
no_disc_error
No disc is detected
0x22
not_initialised_error
The system is not initialised (e.g.
seek on unknown disctype)
0x23
illegal_medium_error
BE detected an unsupported me-
dium during disc recognition
0x24
cd_frequency_error
Measured HF frequency is not
within CD frequency range
0x25
dvd_frequency_error
Measured HF frequency is not
within DVD frequency range
0x26
re-
served(non_existing_bca_
error)
Attempt to read non-existing bca
information
0x27
reserved(bca_read_error)
An error occurred during reading
of bca information
0x28
selftest_error
An error occurred during the self-
test of the BE
0x29
i2c_error
The I2C interface does not oper-
ate
0x2A
laser_pll_error
Laser control pll did not lock or
lost lock on write clock
0x2B
laser_forward_sense_erro
r
Forward sense value didn’t
change with changing laser pow-
er
0x2C
jitter_optimisation_error
An error occurred during optimis-
ation of the jitter
0x2D
tilt_calibration_error
An error occurred during calibra-
tion of the tilt frame
0x2E
reserved
0x2F
frontend_offset_calib_erro
r
The offset in the frontend couldn’t
be calibrated
0x30
reserved
0x31
wsg_calculation_error
An error occurred in the calcula-
tion of the write strategy
0x32
buffer_overrun_error
The buffer input stream overran
the buffer output stream
0x33
return_value_invalid_error The requested information is not
available for this inquiry
0x34
illegal_recording_speed_e
rror
The selected speed is not al-
lowed for a recording on this me-
dium
0x35
opc_media_parameter_err
or
The media parameters (info in
ATIP/ADIP) are invalid or not
read
0x36
opc_record_power_error
The final optimum power was not
reached
0x37
opc_start_power_low_erro
r
OPC start power too low (opti-
mum power is higher)
0x38
opc_start_power_high_err
or
OPC start power too high (opti-
mum power is lower)
error
code
error
meaning