EN 101
3139 785 31532
5.
Firmware Upgrading & Diagnostic Software
Nucleus Name
DS_AMIX_Control
Nucleus Number
1903
Description
Test the controllability of the sound processor by performing a controlled reset
Technical
Test the control register, contains 0x80 after reset and 0x0
after first read of this control register. MSP is reset and
the control register is tested for the 0x80 reset indication
Execution Time
1 second
User Input
None
Error Number
Description
190300
Testing the controllability succeeded
190301
Accessing the MSP failed
190302
Accessing the MSP succeeded, but wrong data was returned
Example
DS:> 1903
190300:
Test OK @
Note
European sets only !!
Nucleus Name
DS_AMIX_Beep
Nucleus Number
1904
Description
Test the beeper functionality of the sound processor
Technical -
Execution Time
3 seconds
User Input
'ON' or 'OFF'
Error Number
Description
190400
Testing the beeper succeeded
190401
Testing the beeper failed
190402
There was an error routing the test path
190402
The user provided the wrong input
Example
DS:> 1904 ON
190400:
Test OK @