2/6
B 00
GB 02872 - Edition 03 - Oct 13
Safety instructions
When the EMO is activated, some internal electrical parts are energized and
water cooling line and N
2
purge line are always supplied.
Risk of electrical shock in case of contact.
Before any intervention, disconnect main electrical cable, water inlet and
outlet quick connectors and N
2
purge connector.
Hazardous voltage enclosed.
Voltage or current hazard sufficient to cause shock.
Disconnect and lockout power before servicing.
Any intervention must be done by trained personnel only.
Trip Hazard.
Route all facilities connections in a manner that will not present a trip hazard
for personnel when accessing the EMO or disconnect device.
If loss of cooling water creates a significant risk, then the water flow must be
monitored externally by the process equipment.
General (continued)
Lock out/tag out (LO/TO) device.
In order to properly secure the pump for installation and/or maintenance,
it is required to lock out/tag out the pump properly in accordance with
OSHA requirement 29 CFR.1910.147.
A padlock (see schematic) allows the lock out /tag out of the pump.
Diameter of hook
between 4 and 6 mm
Installation procedure:
Set the main switch to «0».
Push the grey part of the main switch.
Insert the padlock through hole of the main switch.
Close and lock the padlock.
If loss of purge flow creates a significant risk, then the purge flow must
be monitored externally and a response to loss of purge flow must
be provided by the process equipment and interlocked if necessary.
If pyrophoric materials above the Lower Explosive Limit are sent to the pump
then nitrogen should be supplied at a rate to ensure that concentration is
diluted to be below the Lower Explosive Limit, in addition an interlock should
be provided to ensure that gas flow to the pump is stopped when nitrogen
is lost.
adixen Vacuum Products - Operating instructions - A3P Series