GB 02886 - Edition 03 - Januar
y 09
5/5
C 10
Operating modes
Stand-by power and
high speed control
operation
The «user» plug
B 90
must be wired for these features:
- The
stand-by power function
can be used to reduce the pump power
consumption (stand-by of the pump) during process idle.
- The
high speed function
can be used to reduce the pump consumption
or to increase the pump performance.
«Standby power option»
setting
To change the parameter of the
Standby power opt
from
Disabled
to
Enabled
with the HHDM (accessory), perform the following operations:
Connect the HHDM plug to the HHDM connector on the front or rear
panel.
Set the
Standby power opt
parameter in the
DEFINITION
menu
C 42
as follows:
«High speed option» setting
The
High speed option
parameter in the
DEFINITION
menu
C 42
is set at factory as follows:
A103P
A603P / A1003P
High speed option
Enabled
Disabled
To change the parameter of the
High speed option
perform the following
operations:
Connect the HHDM (accessory) plug to the HHDM connector on the
front or rear panel.
Set the
High speed option
parameter in the
DEFINITION
menu
C 42
as follows:
A message «SP» will be displayed on the HHDM.
HHDM
message
Setting of the monitoring
Equipment command
High speed option
Standby power
option
Via User connector
B 90
SP
Enabled or
Disabled
Enabled
Standby power switch ON
HHDM
message
Setting of the monitoring
Equipment command
High speed option for A103P
Via User connector
B 90
HS
Enabled
Possible to adjust the speed
LS
Disabled
Impossible to modify the speed
adixen Vacuum Products - Operating instructions - A3P Series