Installer manual Fleck 5800 XTR - Programming
78 / 126
Ref. MKT-IM-006 / E - 12.11.2019
Relay Output
auxiliary 1
auxiliary 2
off
alarm
based
auxiliary 1/auxiliary 2
: Contains settings for programming up to two auxiliary relay outputs. There
are four types of signals that can be programmed:
alarm based
: The relay will turn on when the specified alarm condition (or any alarm condition) is
met. The relay will turn off when the alarm is cleared.
cycle based
: The relay will turn on when the valve moves to the specified regeneration cycle steps.
To program, select each cycle step button for which the relay should turn on.
time based
: The relay will turn on and off at up to two specified start and end times.
volume based
: The relay will turn on when the valve has treated a specified volume of water.
Duration can be set for up to two hours.
Info
This option will not be available if regeneration type is set to timeclock.
Press
to save and pass to the relay settings or press
to return to the master settings screen
without saving.
6.3.7.1
Alarm Based
Aux. #: Alarm Based
salt alarm
valve failure
need service/
mainten. req’d
off
on
off
salt alarm
: Turns the relay ON in case of salt alarm.
Mandatory
On the valves of series 5800, salt alarm must be set OFF because the chlorine cell kit
managed by the XTR is not available for those valves.