Installer manual Fleck 5800 XTR - Description
14 / 126
Ref. MKT-IM-006 / E - 12.11.2019
3
Description
3.1
Technical specifications
Design specifications/ratings
Valve body
Fiber-reinforced polymer
Rubber components
EP/EPDM/silicone
Valve material certification
DM174, ACS, EC
Weight (valve with controller)
2 kg (max)
Recommended operating pressure
1.4 - 8.6 bar
Maximum inlet pressure
8.6 bar
Hydrostatic test pressure
20 bar
Water temperature
1 - 43°C
Ambient temperature
0 - 52°C
Flow rates (3.5 bar inlet - valve only)
Continuous service flow (Δp = 1 bar)
4.7 m
3
/h
Peak service flow (Δp = 1.7 bar)
6.1 m
3
/h
Cv*
5.4 gpm
Kv*
4.67 m
3
/h
Maximum backwash flow
(Δp = 1.8 bar)
3.8 m
3
/h
*Cv: Flow rate in gpm across the valve at a pressure drop of 1 psi at 60°F.
*Kv: Flow rate in m
3
/h across the valve at a pressure drop of 1 bar at 16°C.
Valve connections
Tank Thread
2½" - 8NPSM
Inlet/Outlet
¾" or 1"
Riser tube
26.7 mm O.D., 1.05" tube
Drain line
½" O.D.
Brine line (1650)
⅜"
Electrical
Transformer input voltage
100 to 240 VAC
Input supply frequency
50 to 60 Hz
Transformer output voltage
12 VDC
Motor input voltage
12 VDC
Controller input voltage
12 VDC
Controller max. power consumption
6 W
Protection rating
IP 22