Installer manual Fleck 5800 XTR - Troubleshooting
Ref. MKT-IM-006 / E - 12.11.2019
113 / 126
Error screen
display
Cause
Reset and recovery
Flow meter error
No flow detected
No flow has been
detected for 7 days.
Error will clear when a flow pulse is detected. Check
to ensure meter cable is properly installed and meter
spins freely. Clear meter of debris if necessary. If
error continues, call technical support.
No regeneration
for 100 days
The valve has not
regenerated in more
than 100 days.
Initiate a regeneration see Manual regeneration [
Service Interval
Service Interval
controller has
expired.
From within Master Settings, navigate to the
Assistance/Mainten. Interval screen and set a new
Service Interval time.
Memory
Corruption Error
Internal memory
inconsistent or
corrupted.
1. Cycle power to XTR controller.
2. Drain supercap and cycle power to XTR controller.
3. If error continues, call technical support.
Motor Stall
Motor Run-On
No changes
detected in the
optical sensor for
6 seconds
No state changes in
the optical sensor are
detected for
six seconds.
Unplug the unit and plug back in. Allow the control to
attempt to find position again.
Verify the optical sensor is in place with the wires
connected to the circuit board. Verify the motor and
drive train components are in good condition and
assembled properly. Check the valve and verify that
the piston travels freely. Replace/reassemble the
various components as necessary.
Plug the unit back in and observe its behaviour. If the
error reoccurs, unplug the unit, put it into bypass and
contact technical support.