Installer manual Fleck 5800 XTR - Maintenance
Ref. MKT-IM-006 / E - 12.11.2019
95 / 126
9.2
Recommended maintenance plan
9.2.1
Valve used for softening
Items
1 year
2 year
3 year
4 year
5 year
Injector & filter
Clean
Clean
Clean
Clean
Clean/ replace
if necessary
BLFC***
Clean
Clean
Clean
Clean
Clean/ replace
if necessary
DLFC***
Clean
Clean
Clean
Clean
Clean/ replace
if necessary
Bypass (if
present,
contains
Orings***)
Clean
Clean
Clean
Clean
Clean/replace
if necessary
Piston*
-****
-****
Replace
-****
-****
Seals &
spacers*
-****
-****
Replace
-****
-****
Brine valve
Check/clean/
replace if
necessary
Check/clean/
replace if
necessary
Check/clean/
replace if
necessary
Check/clean/
replace if
necessary
Replace
O-rings***
Check for
watertightness
/clean or
replace in case
of leakage
Check for
watertightness
/clean or
replace in case
of leakage
Check for
watertightness
/clean or
replace in case
of leakage
Check for
watertightness
/clean or
replace in case
of leakage
Check for
watertightness
/clean or
replace in case
of leakage
Motor
Check
Check
Check
Check
Replace
Optical sensor
Check
Check
Check
Check
Replace
Gearing
Check
Check
Check
Check
Check/ replace
if necessary
Encoding
wheel
Clean
Clean
Clean
Clean
Clean
Inlet hardness
Check
Check
Check
Check
Check
Residual
hardness
Check/adapt
mixing screw if
necessary
Check/adapt
mixing screw if
necessary
Check/adapt
mixing screw if
necessary
Check/adapt
mixing screw if
necessary
Check/adapt
mixing screw if
necessary
Electronic/
settings**
Check
Check
Check
Check
Check/ replace
if necessary
Transformer**
Check
Check
Check
Check
Check/ replace
if necessary
Meter* (if
present)
Check and
Clean
Check and
Clean
Check and
Clean
Check and
Clean
Replace
Meter cable (if
present)
Check
Check
Check
Check
Check/ replace
if necessary