Installer manual Fleck 5800 XTR - Troubleshooting
112 / 126
Ref. MKT-IM-006 / E - 12.11.2019
10.1
Error detection
If an error in valve or controller function occurs, an alarm will sound and the home screen will
display the error alert button
and the alarm button
.
wed
12:01 am
2 d
Water Treatment
treatment
tank refill
rapid rinse
draw
backwash
Press the alarm button
to mute the alarm.
Press the error alert button
to view information about the error.
If the display is in sleep mode when an error occurs, the screen will turn on for five minutes. The
error will beep for one second per minute until the error is cleared. If the error is not cleared after
five minutes, the screen will switch to power saving mode and display the error alert button as a
screen saver.
10.2
Error alerts
Info
An error alert appears on the home screen if an error condition is detected. Press the
error alert button
to view the error message.
Most error alerts are cleared at regeneration. If the error persists following a
regeneration attempt the appropriate reset and recovery procedure below or contact
technical support.
Error screen
display
Cause
Reset and recovery
Optical Sensor
Undesired change
detected in the
optical sensor
An undesired optical
sensor state change
occurred.
Non-critical error. Extra optical sensor pulse
detected. Press the Regeneration button to advance
motor to clear error.
Flow meter error
Continuous Flow
The flow meter has
reported continuous
flow for more than
24 hours.
Error will clear when flow to meter drops below
0.5 gpm or 1 Lpm. If continuous flow is expected, turn
plumbing leak detection off in Master Settings.
Over current
Motor over
current detected
Motor drew too much
current.
Attempt to perform a manual regeneration. If error