Installer manual Fleck 5800 XTR - Programming
60 / 126
Ref. MKT-IM-006 / E - 12.11.2019
6.2.8
Settings screen
The settings screen allows you to change basic controller settings including time of regeneration
and water hardness. These settings improve the operational efficiency of the system and can be
adjusted independently from other controller settings without needing to enter master settings.
Info
Settings can not be accessed during a regeneration. If a regeneration has to start while
in the settings menu, it will not start until exit the menu.
From the home screen, press the settings button
to access the settings screen.
Settings
day override/
time-driven
regen. time
hardness
300 mg/L
02:00 am
1 d
Press
day override/time-driven
and use the arrows
to adjust the number of days since last
regeneration in which a new regeneration will automatically be run whether one is scheduled or
not.
Press
regen. time
and use the arrows
to adjust the time of day when an automatic
regeneration cycle will begin.
Press
hardness
and use the arrows
to adjust the hardness setting. This value should match
the hardness of the incoming untreated water supply.
Info
If immediate volumetric regeneration has been set, regeneration time will have no
influence on it and regeneration will start as soon as capacity end.
Changing the hardness setting recalculates treatment volume and regeneration
interval. This setting should only be changed on the advice of a professional.
The hardness parameter is not accessible in timeclock and filter mode.
Press
to save your changes or press
to return to the home screen without saving.
Additional features
Additional features may be accessed from the Settings screen by pressing the buttons at the
bottom of the screen:
Master settings
• Displays the master settings screen, which allows you to fully
program the valve.