21
5.1.7 AVG Menu
The main menu "AVG” contains four-pages’ submenus. Refer to Table 5-7.
Table 5-7 AVG Menu
NO
Submenus
Details
1-1
AVG MODE
off
Select the AVG MODE: off.
Press corresponding submenu selection key or
[+/
-
] key to select AVG mode.
2-1
AVG MODE
>3N PLOT
Select the AVG MODE: >3N PLOT.
Press corresponding submenu selection key or
[+/
-
] key to select AVG mode.
2-2 APERTURE
Input diameter of flat-bottomed hole when
making AVG, the max value is related to probe
type, the default is “10mm”.
Press corresponding submenu key to switch
step; press [+] key to increase or [
-
] key to
decrease the value.
2-3 REF
CURVE
Input
Φ
value of lines , the default is 5.0mm.
Press corresponding submenu key to switch
step; press [+] key to increase or [
-
] key to
decrease the value.
2-4 PLOT
Press corresponding submenu key to confirm,
press [+] key to plot automatically.
3-1
AVG MODE
<3N PLOT
Select the AVG MODE: <3N PLOT.
Press corresponding submenu selection key or
[+/
-
] key to select AVG mode.
3-2 AVG
ECHO
Display
measurement
dot number (20 at most).
Press corresponding submenu key to select;
press [+] key to increase or [
-
] key to decrease
the echo points.
4-1
AVG MODE
avg
Select the AVG MODE: avg.
Press corresponding submenu selection key or
[+/
-
] key to select AVG mode.
4-2 REF
CURVE
Set ¢ value of lines; the default is “5.0mm”.
Press corresponding submenu key to switch
step; press [+] key to increase or [
-
] key to
decrease the value.
4-3 COMPENSATE
4-4
FLAW
EQUIVALENT
Display the flaw equivalent value.