Installation Instructions: Form V-418EP
F3, F5, F6, F7, H1, H2, H3 Series Valves
Collective Wiring Manifold
ISSUED: February, 2001
Supersedes: November, 2000
ECN# P28014
Collective Wiring Manifold Installation
1. Assemble Manifold (s), End Plates and Interface Plate
together.
-
F3 Manifold Assembly per instruction V-413DP
-
All other Manifold Assemblies per instructions V-443P
2. Assemble Collective Wiring Module SCD251CB or
SCC191CB by feeding wires into wiring gallery and assemble
Collective Wiring Module to Interface Plate.
3. Connect wires to Manifold Terminal Block(s) per wiring
instructions below
Assembly Limitations
Maximum solenoids energized simultaneously per chart.
25-Pin Sub-D
19-Pin Round
12VDC
18
16
24VAC
22
16
24VDC
24
16
120VAC
24
16
Wiring Instructions
The collective wiring system will accommodate either single
solenoid or double solenoid valves. When ordering a factory
assembled manifold, the end cover of each manifold station is
to be labeled either “Single Address” or Double Address” with
the provided labels. Input signals to the 25-Pin Sub-D Connector
are per Figure 1. Input signals to the 19-Pin Round Connector
are per Figure 2. These signals are connected directly to the
individual manifolds by the colored ribbon cable from the
Collective Wiring Module per Figures 1 and 2.
1. The suggested wiring sequence is to attach the first address
(ribbon lead colored brown) to the first solenoid (Terminal
“14” on the Manifold Terminal Block - see Figures 4 and 5)
of the closed manifold. If that same manifold has a second
solenoid, then the second address (ribbon lead colored
red) is attached to the second solenoid (Terminal “12” on
Pneumatic Division North America
Richland, Michigan 49083
Pneumatic
the Manifold Terminal Block). Or if the second solenoid is on
the second manifold, then the second address (ribbon lead
colored red) is attached to terminal “14” of the second
manifold. Continue this sequence until all addresses have
been connected to their respective solenoids.
2.
The colored leads are to be shortened appropriately to fit
each individual manifold base. Strip 1/4" of the insulation
from each lead and insert bare wire under wire clamp of the
appropriate terminal.
3.
Use the provided jumper leads between manifolds to supply
the common signal. Attach the bare wire to the “COM”
terminal at each manifold.
25-Pin Sub-D Addressing
1
2
3
4
5
6
7
8
9
10
11
12
13
1
3
5
7
9
11
13
15
17
19
21
23
Common
2
4
6
8
10
12
14
16
18
20
22
24
Red
Yellow
Blue
Grey
Black
Red
Yellow
Blue
Grey
Black
Red
Yellow
14
15
16
17
18
19
20
21
22
23
24
25
Brown
Orange
Green
Purple
White
Brown
Orange
Green
Purple
White
Brown
Orange
Manifold
Address
Manifold
Address
Wire
Color
Wire
Color
Pin
Number
Pin
Number
Figure 1
25-Pin Sub-D Pin Callouts
!
!
WARNING
To avoid unpredictable system behavior that can cause personal
injury and property damage:
• Disconnect electrical supply (when necessary) before installation,
servicing, or conversion.
• Disconnect air supply and depressurize all air lines connected to
this product before installation, servicing, or conversion.
• Operate within the manufacturer’s specified pressure, temperature,
and other conditions listed in these instructions.
• Medium must be moisture-free if ambient temperature is below
freezing.
• Service according to procedures listed in these instructions.
• Installation, service, and conversion of these products must be
performed by knowledgeable personnel who understand how
pneumatic products are to be applied.
• After installation, servicing, or conversion, air and electrical
supplies (when necessary) should be connected and the product
tested for proper function and leakage. If audible leakage is present,
or the product does not operate properly, do not put into use.
• Warnings and specifications on the product should not be covered
by paint, etc. If masking is not possible, contact your local
representative for replacement labels.
WARNING
FAILURE OR IMPROPER SELECTION OR IMPROPER USE OF
THE PRODUCTS AND/OR SYSTEMS DESCRIBED HEREIN OR
RELATED ITEMS CAN CAUSE DEATH, PERSONAL INJURY AND
PROPERTY DAMAGE.
This document and other information from Parker Hannifin Corporation,
its subsidiaries and authorized distributors provide product and/or
system options for further investigation by users having technical
expertise. It is important that you analyze all aspects of your application,
including consequences of any failure and review the information
concerning the product or systems in the current product catalog. Due
to the variety of operating conditions and applications for these products
or systems, the user, through its own analysis and testing, is solely
responsible for making the final selection of the products and systems
and assuring that all performance, safety and warning requirements
of the application are met.
The products described herein, including without limitation, product
features, specifications, designs, availability and pricing, are subject
to change by Parker Hannifin Corporation and its subsidiaries at any
time without notice.
EXTRA COPIES OF THESE INSTRUCTIONS ARE AVAILABLE FOR
INCLUSION IN EQUIPMENT / MAINTENANCE MANUALS THAT UTILIZE
THESE PRODUCTS. CONTACT YOUR LOCAL REPRESENTATIVE.
25-Pin Sub-D Cable Specifications
Common Pin “13” is rated for 3 amps. Common wire rating
MUST be greater than total amperage of all solenoids on a
Add-A-Fold assembly.
Example: 12 station manifold, 24 solenoids, 24VDC
24 x .075 = 1.8 total amp rating.