Introduction
Follow these instructions when installing, operating, or servicing
the product.
Port Identification / Connections / Symbols
Port
Single
Dual
No.
Pressure
Pressure
1
Inlet
Exhaust
2
Outlet
Outlet
3
Exhaust
Inlet
4
Outlet
Outlet
5
Exhaust
Inlet
12, 14
Pilot ports for External
Pilot or Remote Pilot
Application Limits
These products are intended for use in general purpose
compressed air systems only. Compliance with the rated
pressure, temperature, and voltage is necessary - see
Installation & Service Instructions (V-440P) packed with valve.
Operating Pressure Range:
Maximum 145 PSIG (1000 kPa)
Ambient Temperature Range:
-15°C to 49°C (5°F to 120°F)
Installation & Service Instructions
V448BP
F & H ISO 5599-2 Manifold Bases With
Interconnect Wiring
ISSUED: August, 2004
Supersedes: February, 2003
Doc. #V-448P, ECN #040722, Rev. 3
Pneumatic Division
Richland, Michigan 49083
Pneumatic
Wiring Instructions
For connection simplicity, the Interconnect Wiring System has a
single common lead with an amperage limit of 3 amps continuous
service. The following chart indicates the upper limit of solenoids
that can be energized simultaneously.
4 2
5
14
12
1 3
5 Port, 2-Position
5 Port, 3-Position
Pressure Center
4 2
5
14
12
1 3
4 2
5
14
12
1 3
5 Port, 3-Position
All Ports Blocked
4 2
5
14
12
1 3
5 Port, 3-Position
Center Exhaust
!
!
WARNING
To avoid unpredictable system behavior that can cause personal injury
and property damage:
•
Disconnect electrical supply (when necessary) before installation,
servicing, or conversion.
•
Disconnect air supply and depressurize all air lines connected to
this product before installation, servicing, or conversion.
•
Operate within the manufacturer’s specified pressure, temperature,
and other conditions listed in these instructions.
•
Medium must be moisture-free if ambient temperature is below
freezing.
•
Service according to procedures listed in these instructions.
•
Installation, service, and conversion of these products must be
performed by knowledgeable personnel who understand how
pneumatic products are to be applied.
•
After installation, servicing, or conversion, air and electrical
supplies (when necessary) should be connected and the product
tested for proper function and leakage. If audible leakage is present,
or the product does not operate properly, do not put into use.
•
Warnings and specifications on the product should not be covered
by paint, etc. If masking is not possible, contact your local
representative for replacement labels.
WARNING
FAILURE OR IMPROPER SELECTION OR IMPROPER USE OF THE
PRODUCTS AND/OR SYSTEMS DESCRIBED HEREIN OR RELATED
ITEMS CAN CAUSE DEATH, PERSONAL INJURY AND PROPERTY
DAMAGE.
This document and other information from Parker Hannifin Corporation,
its subsidiaries and authorized distributors provide product and/or
system options for further investigation by users having technical
expertise. It is important that you analyze all aspects of your application,
including consequences of any failure and review the information
concerning the product or systems in the current product catalog. Due
to the variety of operating conditions and applications for these products
or systems, the user, through its own analysis and testing, is solely
responsible for making the final selection of the products and systems
and assuring that all performance, safety and warning requirements of
the application are met.
The products described herein, including without limitation, product
features, specifications, designs, availability and pricing, are subject to
change by Parker Hannifin Corporation and its subsidiaries at any
time without notice.
!
CAUTION: An interruption of 10 milliseconds or greater
to the power supplied to the solenoid of a solenoid
operated valve may cause the valve to shift. Provision
must be made to prevent power interruption of this
duration to avoid unintended, potentially hazardous,
consequences.
1 of 4
Voltage
25-Pin
19-Pin
12-Pin Round
12-Pin Round
Sub-D
Round
Single
Double
12VDC
18
16
8
16
24VAC
24
16
N/A
N/A
24VDC
24
16
8
16
120VAC
24
16
8
16
Figure 1 (25-Pin Sub-D)
Figure 2 (19-Pin Round)
1
12
11
13
14
15
16
17
18
19
2
3
4
8
9
10
5
7
6
Pin
Number
1
2
3
4
5
6
7
8
9
Address
Number
1
2
3
4
N/A
5
Common
6
7
Pin
Number
10
11
12
13
14
15
16
17
18
19
Address
Number
8
9
Ground
10
11
12
13
14
15
16
1
2
3
4
5
6
7
8
9
10
11
12
13
1
3
5
7
9
11
13
15
17
19
21
23
Common
2
4
6
8
10
12
14
16
18
20
22
24
14
15
16
17
18
19
20
21
22
23
24
25
Manifold
Address
Manifold
Address
Pin
Number
Pin
Number
The Interconnect Wiring System has great flexibility to meet user
wiring needs. Each manifold base has been ordered with either a
single or double address function. The single address circuit board
works with single solenoid valves only. The double address circuit
board works with single or double solenoid valves. As an example,
model F5165BG
M
23A is a single solenoid valve, but with a double
address solenoid circuit board to accommodate a potential conversion
to a double solenoid valve in the future. The end cover of each
manifold base is labeled either “Single Address” or “Double Address”.
Power signals are connected at the 25-Pin Sub-D (Figure 1), 19-Pin
round Collective Wiring Module (Figure 2), or 12-Pin round Collective
Wiring Module (Figure 3). A single address base uses one signal; a
double address base uses two signals, the first to the 14 solenoid,
the second to the 12 solenoid. Signal usage is sequential through the
bases. Any combination of single or double addresses may be used.
For 12-Pin round collective wiring module connectivity to a PLC,
please refer to Allen-Bradley Catalog 1667-SG001A-EN-P for
additional PanelConnect™ information.