Introduction
Follow these instructions when the assembled valve(s) are installed, and
for proper operation. Manifold base installations are described in instruction
sheet V-433BP; subbase installations are described in V-434BP.
Application Limits
These products are intended for use in general purpose compressed air
systems only.
Operating Inlet Pressure:
kPa
psig
bar
Min. (2-Position - Air Return)
140
20
1.4
Min. (2-Position w/Spring
and Air Return)
240
35
2.4
Min. (3-Position)
210
30
2.1
Max. (2 & 3-Position)
996
145
10.0
NOTE: Solenoid operated valves, when specified with external pilot, may
have operating pressures down to vacuum in the main valve. External
pilot pressure and air pilot signals must be greater than or equal to
that in the main valve, but not outside the ratings above.
Ambient Temperature Range:
-15°C to 49°C (5°F to 120°F)
Voltage Range:
Rated V10%, -15%
!
CAUTION: An interruption of 10 milliseconds or greater to the power
supplied to the solenoid of a solenoid operated valve may cause the
valve to shift. Provision must be made to prevent power interruption
of this duration to avoid unintended, potentially hazardous,
consequences.
Port Identification / Connections / Symbols
Port
Single
Dual
No.
Pressure
Pressure
1
Inlet
Exhaust
2
Outlet
Outlet
3
Exhaust
Inlet
4
Outlet
Outlet
5
Exhaust
Inlet
Valves may be used for single outlet (3-Way) by plugging an outlet port.
NOTE: The operator identification describes the ports that are connected
when the operator is energized: operator 12 connects port 1 to
port 2; operator 14 connects port 1 to port 4. Other ports may also
be connected, or blocked – see symbols on the valve.
!
WARNING
F
AILURE OR IMPROPER SELECTION OR IMPROPER USE OF THE PRODUCTS
AND/OR SYSTEMS DESCRIBED HEREIN OR RELATED ITEMS CAN CAUSE
DEATH, PERSONAL INJURY AND PROPERTY DAMAGE.
This document and other information from Parker Hannifin Corporation, its subsidiaries
and authorized distributors provide product and/or system options for further
investigation by users having technical expertise. It is important that you analyze all
aspects of your application, including consequences of any failure and review the
information concerning the product or system in the current product catalog. Due to
the variety of operating conditions and applications for these products or systems, the
user, through its own analysis and testing, is solely responsible for making the final
selection of the products and systems and assuring that all performance, safety and
warning requirements of the application are met.
The products described herein, including without limitation, product features,
specifications, designs, availability and pricing, are subject to change by Parker
Hannifin Corporation and its subsidiaries at any time without notice.
EXTRA COPIES OF THESE INSTRUCTIONS ARE AVAILABLE FOR INCLUSION IN
EQUIPMENT / MAINTENANCE MANUALS THAT UTILIZE THESE PRODUCTS.
CONTACT YOUR LOCAL REPRESENTATIVE.
4 2
5
14
12
1 3
5 Port, 2-Position
5 Port, 3-Position
Center to Outlets
4 2
5
14
12
1 3
4 2
5
14
12
1 3
5 Port, 3-Position
All Ports Blocked
4 2
5
14
12
1 3
5 Port, 3-Position
Outlets to Ends
Installation & Operating Instructions:
V-430DP
F5 Series Valves
ISSUED: September, 2000
Supersedes: October, 1999
ECN# P27805
Pneumatic
!
WARNING
To avoid unpredictable system behavior that can cause personal injury
and property damage:
•
Disconnect electrical supply (when necessary) before installation,
servicing, or conversion.
•
Disconnect air supply and depressurize all air lines connected to this
product before installation, servicing, or conversion.
•
Operate within the manufacturer’s specified pressure, temperature,
and other conditions listed in these instructions.
•
Medium must be moisture-free if ambient temperature is below freezing.
•
Service according to procedures listed in these instructions.
•
Installation, service, and conversion of these products must be
performed by knowledgeable personnel who understand how
pneumatic products are to be applied.
•
After installation, servicing, or conversion, air and electrical supplies
(when necessary) should be connected and the product tested for
proper function and leakage. If audible leakage is present, or the
product does not operate properly, do not put into use.
•
Warnings and specifications on the product should not be covered by
paint, etc. If masking is not possible, contact your local representative
for replacement labels.
NOTE: For dual pressure, the higher pressure is to be at port 3 for single
air operated valves. Solenoid types may have the highest pressure
at either port 3 or 5, as specified.
Installation / Operating Instructions
Valve should be installed with reasonable accessibility for service whenever
possible – repair service kits are available. Keep pipe or tubing lengths to a
minimum with inside clean and free of dirt and chips. Pipe joint compound
should be used sparingly and applied only to the male pipe – never into the
female port. Do not use PTFE tape to seal pipe joints – pieces have a
tendency to break off and lodge inside the unit, possibly causing malfunction.
Air applied to the valve must be filtered to realize maximum component life
.
!
CAUTION: It is recommended that double solenoid and double
remote air pilot operated 2-Position valves be mounted so that the
axis of the valve spool is in the horizontal plane.
Life Expectancy - Normal multi-million cycle life expectancy of these valves
is based on the use of properly filtered and lubricated air at room
temperature. These valves are also designed to be operated under non-
lubricated conditions and will yield millions of maintenance free cycles.
Factory Pre-Lubrication - All valves are pre-lubricated at assembly with
Petroleum Base - Lithium Content grease.
In-Service Lubrication - In-service lubrication is not required; however, if
lubrication is to be used, Parker F442 oil is recommended. This oil is
specially formulated to provide peak performance and maximum service
life from all air operated equipment. Alternative compatible lubricants should
be of a paraffin based mineral oil having 150 to 200 SSU viscosity @
100°F and an aniline point greater than 200°F. (Mobil DTE24 and Sun
Company Sunvis 932 are good examples.)
!
CAUTION: Do not use oils that are synthetic, reconstituted, have
an alcohol content or a detergent additive.
Wiring Instructions
1. Follow all requirements for local and national electrical codes.
2. Remove end cover from base by backing off the two captive screws.
Reassemble cover to base by tightening screws from 0.8 to 1.0 Nm (7
to 9 in-lbs).
3. An external ground connection must be attached to the green ground
screw.
4. Disregard unused wires or terminals.