F3 / F5 Series Valves - Manifold with Flexboard - Option D & E
V-438CP
(F3 Shown)
Collective Wiring End Plate / Transition Plate Kit
(F3 Shown)
Collective Wiring
Module
Top Port
Ground
Screw
Interface plate includes a machined hole for the addition of a
ground screw. An earth ground is recommended for all voltages.
Follow standard electrical protocol.
Note: With CW Transition Plate or F5 Auxiliary Access Manifold,
“Flexboard” is long enough to pass through to the next valve.
Collective Wiring Module
Size
Kit Number
25-Pin Sub-D
SCD251CA
Kit includes: (1) wiring box, (1) gasket, (4) tie rods and
(4) bolts.
•
Single And Double Address “Flexboard” can be
interchanged on the same Add-A-Fold.
•
Single Address “Flexboard” works with Single
Solenoid valves ONLY.
•
Double Address “Flexboard” works with Single or
Double Solenoid valves.
•
Control address schematic determined by “Flexboard”
type, not number of solenoids.
•
Valves with LED / Surge Suppression recommended.
Collective Wiring Manifold Configuration:
• Choose desired number of Valves / Manifolds
with “Flexboard”.
• Choose CW End Plate or CW Transition Plate Kit
– Plug-in and assemble Manifolds and
End Plates together.
• Collective Wir ing Module SCD251CA
– Plug-in and assemble Collective Wiring Module
to Collective Wiring Left Hand End Plate.
Blank
Collective Wiring Assembly
Do Not Twist
Flex Ribbon
Collective Wiring
End Plate
Wiring Instructions
Manifolds can have “Flexboard”s that will accommodate either
single solenoid or double solenoid valves, regardless of the
actual valve. As an example, model F51630GE23 is a single
solenoid valve, but with a double solenoid “Flexboard” to
accommodate a potential conversion to double solenoid type
valve. Care must be taken when wiring to the 25-Pin Sub-D
connector to assure this option is considered. The end cover
of each manifold station is labeled either “Single Address” or
“Double Address”.
Signals to the 25-Pin Sub-D connector are per Figure 1. These
are directed to the individual manifolds by the “Flexboard”. A
single “Flexboard” uses one signal. A double “Flexboard” uses
two signals, the first to the 14 solenoid, the second to the 12
solenoid. Signal usage is sequential through the boards. Any
combination of manifolds with single or double interconnect
boards may be used.
Figure 1
25-Pin Sub-D Pin Callouts
25-Pin Sub-D Addressing
1
2
3
4
5
6
7
8
9
10
11
12
13
1
3
5
7
9
11
13
15
17
19
21
23
Common
2
4
6
8
10
12
14
16
18
20
22
24
14
15
16
17
18
19
20
21
22
23
24
25
“Flexboard”
Address
“Flexboard”
Address
Pin
Number
Pin