Pneumatic Division North America
Richland, Michigan 49083
Pneumatic
!
!
WARNING
To avoid unpredictable system behavior that can cause personal
injury and property damage:
• Disconnect electrical supply (when necessary) before installation,
servicing, or conversion.
• Disconnect air supply and depressurize all air lines connected to
this product before installation, servicing, or conversion.
• Operate within the manufacturer’s specified pressure, temperature,
and other conditions listed in these instructions.
• Medium must be moisture-free if ambient temperature is below
freezing.
• Service according to procedures listed in these instructions.
• Installation, service, and conversion of these products must be
performed by knowledgeable personnel who understand how
pneumatic products are to be applied.
• After installation, servicing, or conversion, air and electrical
supplies (when necessary) should be connected and the product
tested for proper function and leakage. If audible leakage is present,
or the product does not operate properly, do not put into use.
• Warnings and specifications on the product should not be covered
by paint, etc. If masking is not possible, contact your local
representative for replacement labels.
WARNING
FAILURE OR IMPROPER SELECTION OR IMPROPER USE OF
THE PRODUCTS AND/OR SYSTEMS DESCRIBED HEREIN OR
RELATED ITEMS CAN CAUSE DEATH, PERSONAL INJURY AND
PROPERTY DAMAGE.
This document and other information from Parker Hannifin Corporation,
its subsidiaries and authorized distributors provide product and/or
system options for further investigation by users having technical
expertise. It is important that you analyze all aspects of your application,
including consequences of any failure and review the information
concerning the product or systems in the current product catalog. Due
to the variety of operating conditions and applications for these products
or systems, the user, through its own analysis and testing, is solely
responsible for making the final selection of the products and systems
and assuring that all performance, safety and warning requirements
of the application are met.
The products described herein, including without limitation, product
features, specifications, designs, availability and pricing, are subject
to change by Parker Hannifin Corporation and its subsidiaries at any
time without notice.
Application Limits
These products are intended for use in general purpose compressed
air systems only.
Operating Pressure Range:
Maximum: 145 PSIG (1000 kPa)
Minimum: See Chart
Operator /
Internal Pilot
Min. PSIG (kPa)
Function
1
Single Solenoid - 2-Pos
2
Double Solenoid- 2-Pos
20
3
Single Remote - 2-Pos
(138)
4
Double Remote Pilot - 2-Pos
Vacuum
5, 6, 7
Double Solenoid - 3-Pos
30
(207)
8, 9, 0
Double Remote Pilot - 3-Pos
Vacuum
E
Single Solenoid - 2-Pos
Air Return / Spring Assist
35
F
Single Remote Pilot - 2-Pos
(241))
Air Return / Spring Assist
External Pilot *
All
“F” Series
Vacuum
*External Pilot Pressure / Remote Pilot Signal - 35-145 PSIG (241-1000 kPa).
Ambient Temperature Range:
-15°C to 49°C (5°F to 120°F)
Voltage Range:
Rated V10%, -15%
!
!
CAUTION: Solenoid versions of this valve contain solid
state components that can be damaged by transient voltage
spikes, over-voltage or high temperature. To protect against
premature solenoid failure, please read and adhere to the
following:
If this solenoid operated valve is used in a circuit with other
inductive loads. The solenoid should be electrically protected
with a voltage suppression device (e.g. transient voltage
suppressor or varistor) that has a minimum rating of 1.6 times
the rated voltage of the solenoid valve and sufficient capacity to
dissipate the energy of other inductive loads.
!
Installation & Service Instructions
V-449P
F & H Selector Regulator Installation
ISSUED: February, 2001
Supersedes: None
NPR# 1978
Introduction
Follow these instructions when installing, operating, or servicing the
product.
CAUTION: It is recommended that double solenoid and
double remote air pilot operated 2-Position valves be
mounted so that the axis of the valve spool is in the
horizontal plane.
Service Kits
PS3439P
Regulator Kit
PS3445P
Manual Bonnet Assembly
PS3447P
Air Pilot Bonnet Assembly
PS3450030P
30 PSIG Spring Conversion Kit
PS3450060P
60 PSIG Spring Conversion Kit
PS3450125P
125 PSIG Spring Conversion Kit
PS3509P
Pilot Plug Kit
PS3548P
Independent By-Pass Plate
PS3540P
Sandwich Regulator Mounting Stud Kit
Lubrication
Factory Pre-lubed. If lubricating in service, use Parker F440 oil or
equivalent paraffin based mineral oil with 150 to 200 SSU viscosity
@100°F.
CAUTION: Do not use oils that are synthetic, reconstituted,
have an alcohol content or a detergent additive.
4
2
14
Selector Regulator with
4-Way, 2-Position Valve
3
1
5