1-58
Programming Your Application
690+ Series Frequency Inverter
OP STATION
The operator station blocks allow the operation of the Operator Station control keys to be
customised.
OP STATION 1 is associated with the Operator Station port.
OP STATION 2 is associated with the Communications port (P3).
MMI Menu Map
1
SETUP
2
MENUS
3
OP STATION
4
OP STATION 1
4
OP STATION 2
ENABLED
KEYS
OP
VERSION
Op Station 1
–
OP VERSION [230]
–
0000
00F0
–
[127] ENABLED KEYS
–
Op Station 2
–
OP VERSION
[1110]
–
0000
00F0
–
[1109] ENABLED KEYS
–
OP VERSION
Range: 0x0000 to 0xFFFF
Displays the software version of the Operator Station. It is cleared to 0x0000 if no Operator
Station is connected.
Parameter Descriptions
ENABLED KEYS
Range:
0x0000 to 0xFFFF
The following keys on the Operator Station can be enabled or disabled separately. The
combination produces the parameter setting as in the table below.
Parameter Setting RUN
L/R
JOG
DIR
0000
0010
0020
0030
0040
0050
0060
0070
0080
0090
00A0
00B0
00C0
00D0
00E0
00F0
-
-
-
-
-
-
-
-
ENABLED