![Parker 690+ series Product Manual Download Page 229](http://html.mh-extra.com/html/parker/690-series/690-series_product-manual_755642229.webp)
Application Macros
5-19
690+ Series Frequency Inverter
Macro 7: Phase/Register
This macro is to be used in a slave drive set up for phase/register control. The slave will
get the line speed setpoint from the master drive via the system port (serial port using the
5703 setpoint repeater). This provides the highest accuracy and least lag. If this is not
possible, the speed demand should be derived from the master encoder using the
Encoder Speed function block, or over the network.
Note:
Register control is enabled by setting REGISTER::RESET = FALSE
If Auto-gearing is enabled, then it is important that
PHASE CONFIGURE::SCALE A = PHASE CONFIGURE::SCALE B
Control Wiring I/O
Terminal
Name
Purpose
Comment
6
ANALOG OUTPUT 1
Ramp Output
absolute speed demand
0V = 0%, 10V = 100%
7
ANALOG OUTPUT 2
Speed Feedback
-10V = -100%, 10V = 100%
8
ANALOG OUTPUT 3
Torque
Feedback
-10V = -100%, 10V = 100%
12
DIGITAL INPUT 1
Run Forward
24V = Run forward
13
DIGITAL INPUT 2
Run Reverse
24V = Run reverse
14
DIGITAL INPUT 3
Not Stop
24V = RUN FWD and RUN
REV signals latched
0V = RUN FWD and RUN REV
signals not latched
15
DIGITAL INPUT 4
Reverse
24V = Reverse
16
DIGITAL INPUT 5
Jog
24V = Jog
17
DIGITAL INPUT 6
Drive Enable
24V = Drive Enable
18
DIGITAL INPUT 7
Fast Stop
0V = Fast Stop
21, 22
DIGITAL OUTPUT 1
Health
0V = Tripped, i.e. not healthy
23, 24
DIGITAL OUTPUT 2
At Zero Speed
0V = At Zero Speed Feedback
25, 26
DIGITAL OUTPUT 3
Switched On
0V = Open,
24V = Swtiched On
System Board
A2
DIGITAL INPUT 11
Inch Advance
A3
DIGITAL INPUT 12
Inch Retard
A4
DIGITAL INPUT 13
Reset
5703
P3
Master Line Speed Demand
The Operator Menu for
Macro 7
The default Operator Menu is shown below.
System Board Terminals (option)
Terminal
No.
Name
Range
Description
1
External 0V
User-supplied 0V reference
2
DIGIO11
Configurable digital input/output
3
DIGIO12
Configurable digital input/output
4
DIGIO13
Configurable digital input/output
5
DIGIO14
Configurable digital input/output
6
DIGIO15
Configurable digital input/output
1
External 24V In
24V dc (±10%) 1A
User-supplied power supply
2
Reference Encoder A
Input
3
Reference Encoder /A
Input
4
Reference Encoder B
Input
5
Reference Encoder /B
Input
6
Reference Encoder Z
Input
7
Reference Encoder /Z
Input
8
Encoder Supply Out
5V, 12V, 18V, 24V
User selectable (max load 500mA)
9
External 0V
User-supplied 0V reference
1
Slave Encoder A
Input
2
Slave Encoder /A
Input
3
Slave Encoder B
Input
4
Slave Encoder /B
Input
5
Slave Encoder Z
Input
6
Slave Encoder /Z
Input
1
Repeat Encoder Output A
Output
2
Repeat Encoder Output /A
Output
3
Repeat Encoder Output B
Output
4
Repeat Encoder Output /B
Output
5
Repeat Encoder Output Z
Output
6
Repeat Encoder Output /Z
Output
1 2 3 4 5 6
Terminal A
1 2 3 4 5 6 7 8 9
Terminal B
1 2 3 4 5 6
Terminal C
1 2 3 4 5 6
Terminal D
SPEED DEMAND
DRIVE FREQUENCY
MOTOR CURRENT
TORQUE FEEDBACK
OPERATOR MENU
SETPOINT (REMOTE)
DC LINK VOLTS