![Parker 690+ series Product Manual Download Page 119](http://html.mh-extra.com/html/parker/690-series/690-series_product-manual_755642119.webp)
Programming Your Application
1-111
690+ Series Frequency Inverter
STABILISATION
Designed for VOLTS/Hz motor Control
Mode.
Enabling this function reduces the problem of
unstable running in induction motors. This can be experienced at approximately half full speed,
and under low load conditions.
Stabilisation
TRUE – [128] ENABLE
–
MMI Menu Map
1
SETUP
2
MOTOR CONTROL
3
STABILISATION
ENABLE
Parameter Descriptions
ENABLE
Range: FALSE / TRUE
Enables (or disables) the stabilisation function.