3-4
Serial Communications
690+ Series Frequency Inverter
Interaction with the 6901 Operator Station
The file transfer process shares a RAM buffer with the operator station cloning feature. If a
clone save or restore is started while a file transfer is in progress, then the file transfer will be
aborted.
Note:
The file transfer feature may not be used to directly read a file from the operator station
or to write a file to the operator station.
File Names
The drive may contain several Configuration files. Each of these contains all application data
with the exception of those parameters that are motor or frame size specific. Configuration file
names may be between one and eleven characters long and have an extension of ".CFG". The
default Configuration file name is "APPLICATION.CFG".
Motor and frame size specific data is held in the file "MOTOR 1.MOT".