Parameter Specification
2-51
690+ Series Frequency Inverter
FRAME F – 500V Build Power Dependent Defaults
Constant Torque
Quadratic Torque
Parameter
Function Block
Tag
55kW
75kW
90kW
75kW
90kW
110kW
ACCEL TIME
REFERENCE RAMP
258 30.0 30.0 30.0 30.0 30.0 30.0
AUTO
BOOST
FLUXING
108 0.00 0.00 0.00 0.00 0.00 0.00
BASE
FREQUENCY
MOTOR
DATA
1159 50.0 50.0 50.0 50.0 50.0 50.0
CONTROL MODE
MOTOR DATA
1157
VOLTS
/ HZ
VOLTS
/ HZ
VOLTS
/ HZ
VOLTS
/ HZ
VOLTS
/ HZ
VOLTS
/ HZ
DECEL
TIME
REFERENCE
RAMP 259 30.0 30.0 30.0 30.0 30.0 30.0
DEFLUX
DELAY
PATTERN
GEN
100 4.0 4.0 4.0 4.0 4.0 4.0
ENCODER INVERT
FEEDBACKS
567
FALSE FALSE FALSE FALSE FALSE FALSE
ENCODER
LINES
FEEDBACKS
566 2048 2048 2048 2048 2048 2048
ENCODER
SUPPLY
FEEDBACKS
761 10.0 10.0 10.0 10.0 10.0 10.0
FIXED
BOOST
FLUXING
107 0.00 0.00 0.00 0.00 0.00 0.00
INJ BASE VOLTS
INJ BRAKING
739
75.00
75.00
75.00
75.00
75.00
75.00
INJ DC LEVEL
INJ BRAKING
581
1.25
1.25
1.25
1.25
1.25
1.25
INJ DC PULSE
INJ BRAKING
579
2.0
2.0
2.0
2.0
2.0
2.0
INJ DEFLUX TIME
INJ BRAKING
710
2.0
2.0
2.0
2.0
2.0
2.0
INJ FINAL DC
INJ BRAKING
580
3.0
3.0
3.0
3.0
3.0
3.0
INJ
FREQUENCY
INJ
BRAKING
577 6.0 6.0 6.0 6.0 6.0 6.0
LEAKAGE
INDUC
MOTOR
DATA
120 7.89 5.80 5.07 7.89 5.80 5.07
MAG
CURRENT
MOTOR
DATA
65 23.28 31.68 36.24 23.28 31.68 36.24
MAX
SPEED
SETPOINT
SCALE 1032 1500 1500 1500 1500 1500 1500
MOTOR
CONNECTION
MOTOR
DATA
124 STAR STAR STAR STAR STAR STAR
MOTOR CURRENT
MOTOR DATA
64
77.60
105.60
120.80
77.60
105.60
120.80
MOTOR
POLES
MOTOR
DATA 84 4 4 4 4 4 4
MOTOR
VOLTAGE
MOTOR
DATA
1160 500.0 500.0 500.0 500.0 500.0 500.0
MOTOR
VOLTS
VOLTAGE
CONTROL 122 500.0 500.0 500.0 500.0 500.0 500.0
MOTORING
LIMIT
SLIP
COMP
85 150.0 150.0 150.0 150.0 150.0 150.0
MUTUAL INDUC
MOTOR DATA
121
31.58 23.20 20.28 31.58 23.20 20.28
NAMEPLATE
RPM
MOTOR
DATA
83
1475.0 1475.0 1480.0 1475.0 1475.0 1480.0
OVERLOAD
MOTOR
DATA
1164
2.2 2.2 2.2 2.2 2.2 2.2
POWER
MOTOR
DATA
1158 55.00 75.00 90.00 55.00 75.00 90.00
POWER
FACTOR
MOTOR
DATA
242 0.86 0.87 0.90 0.86 0.87 0.90
QUADRATIC TORQUE
FEEDBACKS
50
FALSE FALSE FALSE FALSE FALSE FALSE
REFLUX
TIME
FLYCATCHING 709 6.0 6.0 6.0 6.0 6.0 6.0
REGEN
LIMIT
SLIP
COMP
86 150.0 150.0 150.0 150.0 150.0 150.0
ROTOR TIME CONST
MOTOR DATA
1163
607.30
607.30
759.12
607.30
607.30
759.12
SEARCH
BOOST
FLYCATCHING
32 15.00 15.00 15.00 15.00 15.00 15.00
SEARCH
TIME
FLYCATCHING
574 15.0 15.0 15.0 15.0 15.0 15.0
SEARCH
VOLTS
FLYCATCHING
573 8.00 8.00 8.00 8.00 8.00 8.00
SPEED INT TIME
SPEED LOOP
1188
100
100
100
100
100
100
SPEED PROP GAIN
SPEED LOOP
1187
20.00
20.00
20.00
20.00
20.00
20.00
STATOR
RES
MOTOR
DATA
119 0.2480 0.1822 0.1593 0.2480 0.1822 0.1593
SYMMETRIC TIME
REFERENCE RAMP 267 30.0 30.0 30.0 30.0 30.0 30.0
TRIP THRESHOLD
PWR LOSS CNTRL
1266
447.0
447.0
447.0
447.0
447.0
447.0
VHZ
BASE
FREQ
FLUXING
106 50.0 50.0 50.0 50.0 50.0 50.0