![Parker 690+ series Product Manual Download Page 64](http://html.mh-extra.com/html/parker/690-series/690-series_product-manual_755642064.webp)
1-56
Programming Your Application
690+ Series Frequency Inverter
NAMEPLATE RPM
Range: 0.0 to 32000.0 rpm
This parameter contains the motor nameplate full-load rated speed. This is the motor speed in
rpm at base frequency minus full load slip.
MOTOR CONNECTION
Range: Enumerated - see below
This parameter contains the motor nameplate connection.
Enumerated Value
:
Motor Connection
0 : DELTA
1 : STAR
MOTOR POLES
Range: Enumerated - see below
This parameter contains the motor nameplate pole-pairs.
Enumerated Value
:
Motor Poles
0 : 2 pole
1 : 4 pole
2 : 6 pole
3 : 8 pole
4 : 10 pole
5 : 12 pole
POWER FACTOR
Range: 0.50 to 0.99
This parameter contains the motor nameplate full-load power factor.
OVERLOAD
Range
:
1.0 to 5.0
This parameter contains the allowable motor overload factor. It is used to match the inverter
current measurement range to the motor. The inverter is set up so that the
Motor Current x
Overload
can be measured up to a maximum of 2 x the Inverter constant torque current rating.
The OVERLOAD parameter has no effect on the current, inverse time or torque limits.
STATOR RES
Range: 0.0000 to 250.0000
Ω
This parameter contains the motor model per-phase stator resistance as determined by Autotune.
LEAKAGE INDUC
Range: 0.0 to 300.0 mH
This parameter contains the motor model per-phase leakage inductance as determined by
Autotune.
MUTUAL INDUC
Range: 0.0 to 3000.0 mH
This parameter contains the motor model per-phase mutual inductance as determined by
Autotune.
ROTOR TIME CONST
Range: 10.00 to 3000.00
This parameter contains the motor model rotor time constant as determined by Autotune.