Programming Your Application
6-35
590 Series DC Digital Converter
Functional Description
Link 11 & Link 12
-1
x
|x|
Aux Source
Mode
Source
Advanced
Dest
Switch
Inverter
AND
OR
Sign Chg
Modulus
Comparator
Mode
Description
SWITCH
If ADVANCED = OFF
DESTINATION = SOURCE
If ADVANCED = ON
DESTINATION = AUX SOURCE
INVERTER
If ADVANCED = OFF
DESTINATION = SOURCE
If ADVANCED = ON
DESTINATION = Logic Inversion of SOURCE
AND
If ADVANCED = OFF
DESTINATION = SOURCE
If ADVANCED = ON
DESTINATION = SOURCE AND AUX SOURCE
OR
If ADVANCED = OFF
DESTINATION = SOURCE
If ADVANCED = ON
DESTINATION = SOURCE OR AUX SOURCE
SIGN CHANGER
If ADVANCED = OFF
DESTINATION = SOURCE
If ADVANCED = ON
DESTINATION = Value sign change of SOURCE
MODULUS
If ADVANCED = OFF
DESTINATION = SOURCE
If ADVANCED = ON
DESTINATION = Modulus of SOURCE
COMPARATOR
If ADVANCED = OFF
DESTINATION = SOURCE
If ADVANCED = ON
If SOURCE < AUX SOURCE
DESTINATION = 0
If SOURCE > AUX SOURCE
DESTINATION = 1
Summary of Contents for 590 series
Page 12: ...605 Frequency Inverter HA389591 Issue 1 Contents Contents Page Cont 12...
Page 16: ...1 4 Getting Started 590 Series Digital Converter...
Page 22: ...2 6...
Page 64: ...3 42 Installing the Converter 590D DC Digital Converter HA467078...
Page 82: ...4 18 Operating the Converter 590 Series DC Digital Converter...
Page 90: ...5 8 The Man Machine Interface MMI 590 Series DC Digital Converter...
Page 168: ...9 6 Control Loops 590 Series DC Digital Converter...
Page 222: ...13 14 Standard and Optional Equipment 590 Series DC Digital Converter...
Page 234: ...15 2 The Default Application 590 Series DC Digital Converter...
Page 242: ......