Operating the Converter
4-17
590 Series DC Digital Converter
Normal Starting Method
To achieve a normal start of the Converter:
1.
Apply 24V to Terminal C5 (Enable)
2.
Apply 24V to Terminal C3 (Start)
Note:
The Converter will not start if there are alarms present, or if Terminals B8 (Program Stop)
or B9 (Coast Stop) are low, 0V.
Ensure that Program Stop and Coast Stop are valid before Start/Run is applied.
Advanced Starting Methods
Starting Several Converters Simultaneously
1.
Apply 24V to Terminal C3 (Start)
2.
Use Terminal C5 (Enable) to synchronise the start-up of the Converters
Jog
1.
Apply 24V to Terminal C5 (Enable)
2.
Apply 24V to Terminal C4 (Jog Mode)
Note:
The Converter will not start if there are alarms present.
The Converter can be started using JOG SPEED 1, JOG SPEED 2 (allowing for two different
setpoints, or perhaps to provide an Inch Forward/Inch Reverse).
Refer to Chapter 6: “Programming Your Application” - JOG/SLACK for further information.
Also refer to the STOP RATES function block: the CONTACTOR DELAY parameter is used to
prevent multiple operations of the main contactor from rapid use of the Jog switch.
Crawl
1.
Apply 24V to Terminal C3 (Start)
2.
Apply 24V to Terminal C4 (Jog Mode)
Note:
The Converter will not start if there are alarms present.
Start the Converter using a crawl speed, in Forward or Reverse.
Refer to Chapter 6: “Programming Your Application” - JOG/SLACK for further information.
Summary of Contents for 590 series
Page 12: ...605 Frequency Inverter HA389591 Issue 1 Contents Contents Page Cont 12...
Page 16: ...1 4 Getting Started 590 Series Digital Converter...
Page 22: ...2 6...
Page 64: ...3 42 Installing the Converter 590D DC Digital Converter HA467078...
Page 82: ...4 18 Operating the Converter 590 Series DC Digital Converter...
Page 90: ...5 8 The Man Machine Interface MMI 590 Series DC Digital Converter...
Page 168: ...9 6 Control Loops 590 Series DC Digital Converter...
Page 222: ...13 14 Standard and Optional Equipment 590 Series DC Digital Converter...
Page 234: ...15 2 The Default Application 590 Series DC Digital Converter...
Page 242: ......