![Parker 590 series Product Manual Download Page 100](http://html2.mh-extra.com/html/parker/590-series/590-series_product-manual_3705605100.webp)
6-10
Programming Your Application
590 Series DC Digital Converter
AUX PORT P2
This function block configures the port for
connecting to a suitable unit, i.e. the 5721
Operator Station for controlling the 5720
Quadraloc controller.
MMI Menu Map
1
SERIAL LINKS
2
AUX PORT P2
SRL LINK ENABLE
GROUP ID (GID)
UNIT ID (UID)
PROTOCOL
BAUD
RATE
ESP SUP. (ASCII)
CHANGEBAND
(BIN)
ERROR
REPORT
PNO.7
AUX PORT P2
ENABLED – [147] SRL LINK ENABLE
–
0
–
[140] GROUP ID (GID)
–
0
–
[141] UNIT ID (UID)
–
ASCII
–
[149] PROTOCOL
–
9600
–
[151] BAUD RATE
–
DISABLED
–
[153] ESP SUP. (ASCII)
–
0.00%
–
[145] CHANGEBAND (BIN)
–
00C0
–
[150] ERROR REPORT
–
FFFF
–
[148] PNO. 7
–
Parameter Descriptions
SRL LINK ENABLE
Range:
ENABLED/DISABLED
Enables port operation.
GROUP ID (GID)
Range: 0 to 7
The Parker SSD Drives protocol group identity address.
UNIT ID (UID)
Range: 0 to 15
The Parker SSD Drives protocol unit identity address.
PROTOCOL
Range: See below
Selects the protocol to be used. The selections are:
ASCII
BINARY
OPTION (select OPTION if say a Profibus option is fitted)
BAUD RATE
Range: See below
Selects the Baud Rate.
300
600
1200
2400
4800
9600 (default)
19200
ESP SUP. (ASCII)
Range:
ENABLED/DISABLED
Enable if communicating with a unit using Parker SSD Drive’s own ESP protocol.
CHANGEBAND (BIN)
Range: 0.00% to 327.67%
Percentage change in value to trigger a BINARY Enquiry Poll update.
ERROR REPORT
Range: 0000 to FFFF
Displays the last error as a hexadecimal code. Writing any value to this parameter will set the
value to >00C0 (No Error). Refer to Chapter 14: “Serial Communications” - Reference for a list
of codes.
PNO. 7
Range: 0000 to FFFF
Control word for Multi-Parameter Polling (refer to the COMMS Option Board Technical
Manual - Parameter Specification Tables.
Summary of Contents for 590 series
Page 12: ...605 Frequency Inverter HA389591 Issue 1 Contents Contents Page Cont 12...
Page 16: ...1 4 Getting Started 590 Series Digital Converter...
Page 22: ...2 6...
Page 64: ...3 42 Installing the Converter 590D DC Digital Converter HA467078...
Page 82: ...4 18 Operating the Converter 590 Series DC Digital Converter...
Page 90: ...5 8 The Man Machine Interface MMI 590 Series DC Digital Converter...
Page 168: ...9 6 Control Loops 590 Series DC Digital Converter...
Page 222: ...13 14 Standard and Optional Equipment 590 Series DC Digital Converter...
Page 234: ...15 2 The Default Application 590 Series DC Digital Converter...