6-24
Programming Your Application
590 Series DC Digital Converter
DIGITAL INPUTS
This function block allows the user to
control the digital operating parameters
of the software. The digital input can be
configured to point to a destination
location and to set that destination TRUE
or FALSE depending upon programmable values.
Functional Description
The destination for a digital input can be any valid Tag No, this means that a digital input can be
used to select one of two values for a given parameter. It is also possible to treat the values for
TRUE and FALSE as destination tags from other functions or inputs.
With regard to destinations
expecting logic parameters, 0.00% is
regarded as Logic 0 and any other
value is regarded as Logic 1. This
refers to the values set in both
VALUE TRUE and VALUE
FALSE.
Inverting the digital input is
therefore simple; set VALUE TRUE
to 0.00% and VALUE FALSE to
0.01% or any other non-zero
number.
DIGIN 1 (C6)
–
OUTPUT [102]
–
90
0.01 %
–
[103] VALUE TRUE
–
0.00 %
–
[104] VALUE FALSE
–
–
DIGIN 1 (C6) [ 71]
–
OFF
DIGIN 2 (C7)
–
OUTPUT [105]
–
118
0.01 %
–
[106] VALUE TRUE
–
0.00 %
–
[107] VALUE FALSE
–
–
DIGIN 2 (C7) [ 72]
–
OFF
DIGIN 3 (C8)
–
OUTPUT [108]
–
119
0.01 %
–
[109] VALUE TRUE
–
0.00 %
–
[110] VALUE FALSE
–
–
DIGIN 3 (C8) [ 73]
–
OFF
MMI Menu Map
1
SYSTEM
2
CONFIGURE I/O
3
DIGITAL INPUTS
4
DIGITAL INPUT C4
4
DIGITAL INPUT C5
DESTINATION
TAG
MMI Menu Map
1
SYSTEM
2
CONFIGURE I/O
3
DIGITAL INPUTS
4
DIGIN 1 (C6)
4
DIGIN 2 (C7)
4
DIGIN 3 (C8)
VALUE FOR TRUE
VALUE FOR FALSE
DESTINATION
TAG
Parameter Descriptions
VALUE TRUE
Range: -300.00 % to 300.00%
The value that OUTPUT assumes when input is TRUE.
VALUE FALSE
Range: -300.00% to 300.00%
The value that OUTPUT assumes when input is FALSE.
DIGIN 1 (C6) to DIGIN 3 (C8)
Refer to the DIAGNOSTICS function block description, page 6-18.
OUTPUT
Range: 0 to 499
(DESTINATION TAG)
The destination Tag No. of the assumed value.
Configurable Digital Inputs
Output
Value True
Value False
DIAGNOSTIC
Summary of Contents for 590 series
Page 12: ...605 Frequency Inverter HA389591 Issue 1 Contents Contents Page Cont 12...
Page 16: ...1 4 Getting Started 590 Series Digital Converter...
Page 22: ...2 6...
Page 64: ...3 42 Installing the Converter 590D DC Digital Converter HA467078...
Page 82: ...4 18 Operating the Converter 590 Series DC Digital Converter...
Page 90: ...5 8 The Man Machine Interface MMI 590 Series DC Digital Converter...
Page 168: ...9 6 Control Loops 590 Series DC Digital Converter...
Page 222: ...13 14 Standard and Optional Equipment 590 Series DC Digital Converter...
Page 234: ...15 2 The Default Application 590 Series DC Digital Converter...
Page 242: ......