220
Gemini GV6K/GT6K Command Reference
NOTE
: The
OUTLVL
setting is NOT saved in battery-backed RAM; therefore, on power up or reset, the
OUTLVL
setting will default to the factory default setting (thus, the
OUTLVL
command is a good candidate
for inclusion in your
STARTP
program).
The number of external outputs varies by the configuration of I/O bricks used. Refer to page
8
for details.
Onboard Outputs
OUTLVL
Setting
OUT
State *
Current
TOUT
status
Relationships:
OUTLVL0
(default)
OUT1
Sinking current
1
OUTLVL0
OUT0
No current flow
0
OUTLVL1
OUT1
No current flow
1
OUTLVL1 OUT0
Sinking current
0
* The output is “active” when it is commanded by the
OUT
command
(for example,
OUTxx1
activates output #3).
Outputs on Expansion I/O Bricks
:
•
Sinking vs. Sourcing Outputs. On power up, the Gem6K drive auto-detects the type of output SIM
installed on each external I/O brick, and automatically changes the
OUTLVL
setting accordingly. If
sinking (NPN) outputs or Reed Relay outputs are detected,
OUTLVL
is set to active low (
OUTLVL0
); if
sourcing (PNP) outputs are detected,
OUTLVL
is set to active high (
OUTLVL1
).
•
Disconnect I/O Brick. If the I/O brick is disconnected (or if it loses power), the drive will perform a
kill (all tasks) and set error bit #18. (If you disable the “Kill on I/O Disconnect” mode with
KIOENØ
,
the Gem6K will not perform the kill.) The drive will remember the brick configuration (volatile
memory) in effect at the time the disconnection occurred. When you reconnect the I/O brick, the drive
checks to see if anything changed (SIM by SIM) from the state when it was disconnected. If an
existing SIM slot is changed (different SIM, vacant SIM slot, or jumper setting), the drive will set the
SIM to factory default
INEN
and
OUTLVL
settings. If a new SIM is installed where there was none
before, the new SIM is auto-configured to factory defaults.
Output Type
OUTLVL
Setting
OUT
State *
Current
OUT
/
TOUT
status
LED
•
Relationships:
NPN (sinking)
OUTLVL0
(default)
OUT1
Sinking current
1
ON
NPN
OUTLVL0
(default)
OUT0
No current flow
0
OFF
NPN
OUTLVL1 OUT1
No current flow
1
OFF
NPN
OUTLVL1 OUT0
Sinking current
0
ON
PNP (sourcing)
OUTLVL0
OUT1
No current flow
1
OFF
PNP
OUTLVL0 OUT0
Sourcing current
0
ON
PNP
OUTLVL1
(default)
OUT1
Sourcing current
1
ON
PNP
OUTLVL1
(default)
OUT0
No current flow
0
OFF
Reed Relay
OUTLVL0
(default)
OUT1
Sinking (closed)
1
ON
Reed Relay
OUTLVL0
(default)
OUT0
No flow (open)
0
OFF
Reed Relay
OUTLVL1 OUT1
No flow (open)
1
OFF
Reed Relay
OUTLVL1 OUT0
Sinking (closed)
0
ON
* The output is “active” when it is commanded by the
OUT
,
OUTP
, or
POUT
command (for example,
OUTxx1