53
• “FPS” indicates as field per second or frame per
second when the FIELD/FRAME parameter is set to
FIELD or FRAME in the menu.
Move the cursor to the REC QUALITY parameter by
pressing the
D
or
C
button, then select a recording
image quality by pressing the
+
or
-
button.
SUPER FINE:
For enhanced sharpness (Compression
Rate 1/6)
FINE:
For fine image quality (Compression Rate 1/10)
NORMAL:
For normal image quality (Compression Rate
1/16)
EXTENDED:
For extended time recording quality
(Compression Rate 1/25)
●
Alarm Active Mode
The item lets you select the active mode for group cameras
in Time Lapse Recording when an alarm is received while
recording with the internal programmed timer.
1. Move the cursor to the TRIGGER ACTION parameter in
the menu by pressing the
D
or
C
button.
2. Select the desired active mode for assigned group
cameras by pressing the
+
or
-
button.
REC+ALM:
Enables alarm recording and alarm activa-
tion.
REC:
Enables only alarm recording.
The ALARM display on the monitor is disabled.
OFF:
Deactivates alarm input.
The ALARM display on the monitor is also disabled.
The factory default setting is REC+ALM.
●
Event Recording
These items let you set the recording mode in Time Lapse
Recording when an alarm is received during the recording
with the internal programmed timer.
1. Move the cursor to the EVENT REC MODE parameter
by pressing the
D
or
C
button, then select a recording
time mode by pressing the
+
or
-
button.
The parameters are the same as TIMER REC MODE
except OFF.
For details refer to TIMER REC MODE in this menu.
2. Move the cursor to the REC RATE(MAX) parameter by
pressing the
D
or
C
button, then select a recording
rate by pressing the
+
or
-
button.
For details refer to REC RATE in this menu.
3. Move the cursor to the REC QUALITY parameter by
pressing the
D
or
C
button, then select a recording
image quality by pressing the
+
or
-
button.
For details refer to REC QUALITY in this menu.
4. Move the cursor to the DURATION parameter by press-
ing the
D
or
C
button, then select the alarm recording
duration by pressing the
+
or
-
button.
2S - 6M:
Enables alarm recording for between 2 sec-
onds and 6 minutes.
MANUAL:
Enables alarm recording while the alarm sig-
nal is received from the ALARM port.
CONTINUE:
Enables alarm recording until the REC
STOP is pressed.
The factory default setting is 10S.
5. Move the cursor to the DYNAMIC REC parameter by
pressing the
D
or
C
button, then select an alarm
recording pattern by pressing the
+
or
-
button.
OFF:
Records the images assigned to the group inputs
including the one which has activated the alarm.
ALM-PRI:
Records the alarm input images preferential-
ly over other video inputs.
ALM-ONLY:
Records the particular images that have
activated the alarm.
ALM-MILUTI:
Records multiple alarms adaptively.
The factory default setting is OFF.
6. If the parameter ALM-MULTI is selected for alarm
recording pattern, move the cursor to the REC
RATE(BASE) parameter by pressing the
D
or
C
button,
then select a recording rate by pressing the
+
or
-
button.
The recording rate can be selected as same as REC
RATE(MAX) maximally.
7. Move the cursor to the AUTO COPY parameter by
pressing the
D
or
C
button, then select alarm backup
mode by pressing the
+
or
-
button.
This lets you enable or disable alarm data backup on
the DVD-RAM disk. Refer to the DVD DRIVE SETUP for
details.
OFF:
Disables alarm data backup.
ON:
Enables alarm data backup.
The factory default setting is OFF.
8. Press the
SETUP/ESC
button to return to the previous
program number menu.
Summary of Contents for WJHD500A - Digital Disk Recorder
Page 26: ...26 ...
Page 27: ...27 PREPARATIONS ...
Page 40: ...40 ...
Page 41: ...41 SETUP PROCEDURES ...
Page 78: ...78 ...
Page 79: ...79 OPERATING PROCEDURES ...
Page 128: ...128 ...
Page 129: ...129 PRÉPARATIFS ...
Page 142: ...142 ...
Page 143: ...143 PROCÉDURES DE CONFIGURATION ...
Page 181: ...181 OPROCÉDURES D UTILISATION ...