46
Highlight the box under the “Alarm-Out” heading and press the button. A list of Alarm Outputs appears.
You can associate as many Alarm-Outs with that camera as you wish. When the recorder detects video loss
on the selected camera, it will trigger output signals on all the associated Alarm Output Terminals. You can
also have the recorder’s internal buzzer sound if video is lost on the selected camera.
Note: For the Alarm-Out action, the alarm output and beep you select should be set to the Event
mode in the Alarm-Out Schedule setup screen.
Highlight the box under the “Notify” heading and press the button. You can toggle the entire list On and
Off by highlighting “Notification” and pressing the button. You can toggle the individual items On and Off
by highlighting that item and pressing the button. Highlight “OK” and press the button to accept your
changes.
Highlight the desired box under the “PTZ” heading, and
press the button. A list of PTZ presets appear.
Select the preset position for each PTZ camera, where
you want PTZ cameras to move to when the recorder
detects video loss on the selected camera’s input.
Highlight the box under the “Spot Monitor” heading and
press the button. A list of Spot monitors and
cameras appears. Each Spot monitor can be
associated with a camera. The recorder will display the
associated camera on the Spot monitor whenever it
detects video loss on the selected camera.
Figure 72 : Video Loss - Actions 2 screen
You can save your Video Loss changes by highlighting “Save” and pressing the button. Selecting
“Cancel” exits the screen without saving the changes.
Video Blind
Highlight “Video Blind” in the Event menu and press the button. The “Video Blind” setup screen appears.
The recorder checks to see if anything is blinding the
camera.
Figure 73 : Video Blind - Settings screen
Highlighting the box under the “Sensitivity” heading allows you to adjust the
recorder’s sensitivity to video blind for Black and White independently from 0
(Never) to 15 (most sensitive).
Note: Video blind might NOT be detected for a camera with a very
noisy image especially when set for low sensitivity values.
Figure 74 : Video Blind - Sensitivity screen
Highlighting the box under the “Activation Time” heading allows you to set the duration before the recorder
will report a Video Blind. The recorder will not consider any blinded camera to be a Video Blind if the
detected blindness is less than the Activation Time set on this screen.