ACCESS AUTHORIZATION
■
Control of Access Authorization
User access authorization is controlled as follows.
●
Unlimited access
If neither user nor host authorization is used (set to NOT
USE) in a network, all users may perform the following
operations at access level 3.
• Monitoring live images
• Controlling cameras and other equipment connected to
the WJ-HD500
C
Accessing the WJ-HD500 SETUP MENU requires an
administrator account.
●
Limited access
• Access is limited according to the host access levels
specified in the HOST SETUP window. The HOST
SETUP window is queried using the IP address of the
host requesting access to the WJ-HD500. When
accessing via a proxy server, the access level there-
fore is determined by the IP address of the proxy
server.
• When access is made from a PC not registered in the
HOST SETUP window, the dialog box shown in the
figure prompts the user to enter User Name and
Password. The access level is determined when both
the user name and password are entered.
■
Access Level
Three access levels can be assigned to control access by
users.
More than one user can be assigned the same access
level. While device control commands are given top priority
in the execution chain, there is no priority attached to the
access level. It is possible to designate more than one
network administrator and to change designated
administrators.
●
Administrator (Level 1)
• Monitoring live images
• Input select and camera control
• Playback recorded images
• Recording live images
• Alarm reset operation
• Access to and setup of the WJ-HD500 SETUP MENU.
• Contents upload
●
Monitoring and playback (Level 2)
• Monitoring live images
• Input select and camera control
• Playback recorded images
●
Monitoring only (Level 3)
• Monitoring live images
• Input select and camera control
■
Registration
Administrator level (Level 1) users only can be registered in
the HOST SETUP and USER SETUP windows. Each window
is provided with fields for making the necessary entries.
The factory default setting is USER NAME: admin,
PASSWORD: nil (not required), ACCESS LEVEL: 1. An
"admin" user can change passwords, but is not authorized
to delete users or change access levels.
●
Host Setup Window
A maximum of 8 terminal addresses can be registered in
the HOST SETUP window. Initially there are no addresses
registered.
Enter the host IP address as a dotted (.) notation, for
example. 192.168.0.10. The host name cannot be
specified. The host IP address "0.0.0.0" is invalid.
Select (mark) any of access levels 1 to 3.