11
●
User Deletion
To delete a registered user, follow the procedure shown
below.
1. Select a user name by clicking the pulldown list.
2. Click the
[DELETE]
button to execute the deletion.
■
Host Setup
Clicking the
[HOST]
button in the window, the HOST
SETUP window shown in the figure appears on the display
screen.
The items in the window let you determine to enable or dis-
able host authorization and register or delete hosts (PCs)
that can be accessed to the homepage.
Up to eight hosts can be registered in the system.
●
Host Authorization
Note:
If the access levels is exclusively set to user autho-
rization, select “NOT USE” to disable host authorization
by clicking the button then proceed to set the User
Setup.
1. Select either USE or NOT USE to enable or disable host
authorization.
The factory default setting is NOT USE.
2 Click the
[SET]
button to execute the selection.
●
Host Registration
To register hosts, follow the procedure shown below.
1. Specify the host (PC).
q
Enter a IP address of the host (PC) in the box
w
Select an access level for the host by clicking the
button.
The access level is defined as shown below.
Refer to Access Authorization for further details.
1(ADMIN):
Enables all controls and setup
2(PLAY):
Enables monitoring live images and
playing back the recorded images.
3(USER):
Enables only monitoring live images.
2. Click the
[SET]
button to register the host.
3. Repeat the above steps 1 and 2 to register the other
hosts.
●
Host Deletion
To delete a registered host, follow the procedure shown
below.
1. Select a host address by clicking the pulldown list.
2. Click the
[DELETE]
button to execute the deletion.
■
PS.Data Setup
Clicking the
[PS.Data]
button in the window, the PS.Data
SETUP window shown in the figure will appear on the dis-
play screen.
The items in the window let you set the parameters for com-
munication when the system is controlled with the PS.Data
(Panasonic Security Data) mode.
1. Enter a unit address (001 - 099) of the board for RS-485
communication in the box.
The factory default setting is 001.
2. Enter a group address (00A - 00Z) of the board for RS-
485 communication in the box
The factory default setting is 00A.
3. Select a transmission speed for RS-485 communication
by clicking the pulldown list.
The factory default setting is 9 600 bps.
2400bps 4800bps 9600bps
38400bps 19200bps