21
2. If the parameter SP is selected for recording mode,
select a recording rate by clicking the pulldown list.
1 - 30fps:
Records the selected number of the freeze
images every second.
0.5fps:
Records a freeze image every 2 seconds.
0.4fps:
Records a freeze image every 2.5 seconds.
0.3fps:
Records a freeze image every 3.3 seconds.
0.2fps:
Records a freeze image every 5 seconds.
0.1fps:
Records a freeze image every 10 seconds.
• 30fps is the active selection when the FIELD/FRAME
parameter in the COMMON SETUP window is set to
FIELD.
• 15fps is the active selection when the FIELD/FRAME
parameter in the COMMON SETUP window is set to
FIELD or FRAME 3DIM OFF.
Select a recording image quality by pressing the click-
ing the pulldown list.
SUPER FINE:
For enhanced sharpness (Compression
Rate 1/6)
FINE:
For fine image quality (Compression Rate 1/10)
NORMAL:
For normal image quality (Compression Rate
1/16)
EXTENDED:
For extended time recording quality
(Compression Rate 1/25)
●
Alarm Recording Mode
These items let you set the recording mode in Time Lapse
Recording when an alarm is activated during the recording
with the internal programmed timer.
1. Select a recording time mode by clicking the pulldown
list.
The parameters are the same as TIMER REC MODE.
For details refer to TIMER REC MODE in this window.
2. Select a recording rate by clicking the pulldown list.
For details refer to REC RATE in this menu.
3. Select a recording image quality clicking the pulldown
list.
For details refer to REC QUALITY in this menu.
4. Select the alarm recording duration by clicking the pull-
down list.
10S - 6M:
Enables alarm recording for between 10 sec-
onds and 6 minutes.
MANUAL:
Enables alarm recording while the alarm sig-
nal is received from the ALARM port.
CONTINUE:
Enables alarm recording until the REC
STOP is pressed.
The factory default setting is 10S.
5. Select an alarm recording pattern by clicking the pull-
down list.
OFF:
Records the images assigned to the group inputs
including the one which has activated the alarm.
ALM-PRI:
Records the alarm input images preferential-
ly over other video inputs.
ALM-ONLY:
Records the particular images that have
activated the alarm.
The factory default setting is OFF.
6. Click the
[SET]
button to execute the selections.
7. Click the PROG
✽
SETUP display in the underneath of
the window to return to the previous program number
window.
■
Multi Shot Recording
(Internal Timer)
As described before, the Multi Shot Recording is an event
recording function reacting to an alarm input.
It records the number of images in pre- and post-recording.
Pre-recording is the recorded images during standby, prior
to the input of the alarm signal.
Post-recording is the recorded images after the input of the
alarm signal.
These items let you determine the recording parameters for
Multi Shot Recording assigned in the program number
menu.
(Continued from Program Timer)
Select the recording mode M/S in the program number win-
dow by clicking the pulldown list, then click the
[More]
but-
ton.
The selected Multi Shot Recording window as shown in the
figure will appear on the display.
1. Select a recording rate by clicking the pulldown list.
1 - 30fps:
Records the selected number of freeze
images every second.
Summary of Contents for WJ-HDB502
Page 7: ...7 WJ HDB502 BOARD SETUP ...
Page 13: ...13 WJ HD500 SETUP ...
Page 38: ...39 SYSTEM OPERATIONS ...