Chapter 7
Appendix — Technical information
268 - ENGLISH
Class
Command
Control details
Parameter/response
string
Remark
2
INNM ?
Input terminal name
query
31 / HDMI1
32 / HDMI2
33 / DISPLAYPORT
34 / SDI[SLOT]
Input name of the optional 12G-SDI Terminal Board (Model No.:
TY-SB01QS) installed in <SLOT>
34 / DIGITAL
LINK[SLOT]
Input name of the optional DIGITAL LINK Terminal Board (Model
No.: TY-SB01DL) installed in <SLOT>
34 / PressIT[SLOT]
Input name of the optional Wireless Presentation System
Receiver Board (Model No.: TY-SB01WP) installed in <SLOT>
34 / SLOT
Input name of the Function Board by other manufacturers
installed in <SLOT>
2
IRES ?
Input signal resolution
query
AAAAxBBBB
AAAA: Horizontal resolution
BBBB: Vertical resolution
2
RRES ?
Recommended
resolution query
3840x2400
1920x1200
Returns display resolution.
3840x2400: When [QUAD PIXEL DRIVE] is set to [ON]
1920x1200: When [QUAD PIXEL DRIVE] is set to [OFF]
2
FREZ
Freeze control
0
1
Freeze clear
Freeze (stop)
FREZ ?
Freeze status query
2
POWR
Cooling notification
0
Notifies when the power is turned off.
Warmup notification
1
Notifies when the power is turned on.
2
ERST
Error notification
xxxxxx
Notifies when an error occurs.
2
LKUP
Link up notification
xx:xx:xx:xx:xx:xx
Notifies the MAC address when the PJLink communication
becomes possible.
2
INPT
Input switch
completion notification
31
HDMI1
32
HDMI2
33
DisplayPort
34
SDI
*1
/DIGITAL LINK
*2
/PressIT
*3
/SLOT
*4
2
SRCH
Projector search
ACKN=xx:xx:xx:xx:xx:xx The projector connected to the same network that can
communicate with PJLink will respond with its MAC address.
*1 When the optional 12G-SDI Terminal Board (Model No.: TY-SB01QS) is installed in <SLOT>
*2
When the optional DIGITAL LINK Terminal Board (Model No.: TY-SB01DL) is installed in <SLOT>
*3
When the optional Wireless Presentation System Receiver Board (Model No.: TY-SB01WP) is installed in <SLOT>
*4
When the Function Board by other manufacturers is installed in <SLOT>
PJLink security authentication
A PJLink password for security authentication procedure is required for communication of the PJLink command.
The PJLink password can be set in the [NETWORK] menu
→
[PJLink]
→
[PJLink PASSWORD] (
x
page 204), or
in “[Set up password] page (when accessed by administrator account)” (
x
page 243) of the web control screen.
When communicating the PJLink command without authentication procedure, set the PJLink password as blank.
The factory default setting of the PJLink password is blank.
f
For specifications related to PJLink, visit the following website of Japan Business Machine and Information
System Industries Association.
https://pjlink.jbmia.or.jp/