No. SX-DSV02310 - 91 -
R2.0 Motor
Business
Division,
Appliances Company, Panasonic Corporation
Type_Code
Conventional
New
Title
Index
Unit
Description
Refer to
-
67h
Fan life expectancy
-
-
0.1%
Percent of fan life expectancy.
▪
Because the power on time is recorded in unit of 30
minutes, a turn-on period shorter than 30 minutes is
not recorded.
▪
0 when no fan is installed.
-
-
68h
Capacitor life
expectancy
-
-
0.1%
Percent life expectancy of main power source
capacitor
▪
Because the power on time is recorded in unit of 30
minutes, a turn-on period shorter than 30 minutes is
not recorded.
-
69h
Voltage across PN
-
-
V
Main power source PN voltage
-
401h
71h
RTEX cumulative
communication errors
-
0
Cycle
Total number of RTEX communication errors
▪
Saturation occurs at max. value FFFFh.
The count will be cleared upon restarting of servo
driver or resetting of control power source.
-
411h
81h
Maker use
-
–
– –
-
412h
82h
Maker use
-
–
– –
-
-
83h
Feedback scale
cumulative
communication errors
-
0
Cycle
Total (cumulative) number of communication errors
between feedback scale
▪
Saturation occurs at max. value FFFFh.
The count will be cleared upon restarting of servo
driver or resetting of control power source.
-
-
84h
Feedback scale
cumulative
communication data
errors
-
0
Cycle
Total (cumulative) number of communication errors
between feedback scale
▪
Saturation occurs at max. value FFFFh.
The count will be cleared upon restarting of servo
driver or resetting of control power source.
-
-
91h
Estimation accuracy of
magnetic pole position
-
0
Degree
Estimation accuracy when execution of estimating
magnetic pole position
(Electric angle: 0 – 180 [degree])
Example) When the value is 10, it means estimation
accuracy of magnetic pole position is
within
10 [degree] of electric angle.
▪
The smaller in this value, the better in accuracy.
▪
This accuracy is accuracy estimated from magnetic
pole position estimation method and does not
guarantee actual accuracy. Use it as a reference.
▪
When estimation of magnetic pole position is not
completed, 0 is returned.
▪
When estimation of magnetic pole position is in
execution, 180 is returned.
▪
When estimation of magnetic pole position is error,
180 is returned.
▪
When Pr9.20 (Selection of magnetic pole detection
method)
≠
2 (other than magnetic pole estimation
method), 0 is returned.
-
-
92h
Execution time of
estimation of magnetic
pole position
-
0
ms
Execution time when estimating magnetic pole
position
▪
Value is renewed after completion of magnetic pole
position estimation.
▪
When Pr9.20 (Selection of magnetic pole detection
method)
≠
2 (other than magnetic pole estimation
method), 0 is indicated.
-
-
93h
Maximum travel
distance to plus
direction when
estimating magnetic
pole position
-
0
pulse
(feedback
scale order)
Making starting position for estimation of magnetic
pole position as a base, returns maximum travel
distance [pulse] to plus direction.
▪
Value is renewed after completion of magnetic pole
position estimation.
▪
When Pr9.20 (Selection of magnetic pole detection
method)
≠
2 (other than magnetic pole estimation
method), 0 is indicated.
-
-
94h
Maximum travel
distance to minus
direction when
estimating magnetic
pole position
-
0
Pulse
(feedback
scale order)
Making starting position for estimation of magnetic
pole position as a base, returns maximum travel
distance [pulse] to minus direction.
▪
Value is renewed after completion of magnetic pole
position estimation.
▪
When Pr9.20 (Selection of magnetic pole detection
method)
≠
2 (other than magnetic pole estimation