No. SX-DSV02310 - 64 -
R2.0 Motor
Business
Division,
Appliances Company, Panasonic Corporation
6-5-2 Assignment of external input signals related to return to home sequence
When allocating the return-to-home related external inputs (HOME, POT, NOT, EXT1, EXT2 and EXT3) to the
internal terminals, note the following:
1) When using home position reference trigger, allocation can be made only to latch correction terminals (SI5, SI6
and SI7) through NO contact.
2) EXT1 can be allocated only to SI5, EXT2 only to SI6 and EXT3 only to SI7.
3) When using HOME, POT and NOT as home position reference trigger, HOME can be allocated only to SI5, POT
only to SI6 and NOT only to SI7 through a contact.
Note: When POT or NOT is allocated to the latch correction terminal, a contact is used: drive inhibit input is not
active when cable is disconnected. Therefore, safety must be secured by a different measure such as
mechanical stopper.
4) When allocating EXT1, EXT2, EXT3, HOME, POT or NOT to latch correction terminal (S15, S16 or S17),
allocate the same signal in all control modes.
If the conditions 1) to 3) are not met, Err. 33.8 (External latching input allocation error protection) will occur.
5) If HOME, POT and NOT are not the home reference trigger, they can be allocated to normal terminal (SI1, SI2,
SI3, SI4 and SI8).
Non-latch
correction
terminal
SI1
SI2
SI3
SI4
SI8
EXT1
EXT2
EXT3
HOME
POT
NOT
Logic
a contact or
b contact
a contact or
b contact
a contact or
b contact
a contact or
b contact
Internal
process
a contact or
b contact
Latch correction
terminal
SI5
SI6
SI7
a contact or
b contact
EXT1
EXT2
EXT3
or
or
or
Logic
HOME
POT
NOT
or
a contact or
b contact
a contact or
b contact
Internal
process
Connections to use edge of the sensor signal as home position.
Connections not to use edge of the sensor signal as home position.
2.0
2.0