![Panasonic MINAS-A5NL Series Technical Reference Download Page 61](http://html.mh-extra.com/html/panasonic/minas-a5nl-series/minas-a5nl-series_technical-reference_278153061.webp)
No. SX-DSV02310 - 53 -
R2.0 Motor
Business
Division,
Appliances Company, Panasonic Corporation
6-2 Normal command (Command code:
0h)
Command used for normal operation.
This command is also reference command of non-cyclic command.
Main command: common to 16 byte and 32 byte mode
Command
Response
Byte bit7
6
5
4
3
2
1
0
Byte
bit7
6
5
4
3
2
1
0
0
C
(0)
Update_Counter
MAC-ID
0
R
(1)
Update_Counter
_Echo
Actual_MAC-ID
1
TMG_
CNT
Command_Code (
0h)
1
CMD_
Error
Command_Code_Echo (
0h)
2
2
3
Control_Bits
3
Status_Flags
4 L
4 L
5 ML
5 ML
6 MH
6 MH
7
Command_Data1
H
7
Response_Data1
H
8 L
8 L
9 ML
9 ML
10 MH
10 MH
11
Command_Data2
H
11
Response_Data2
H
12 L
12 L
13 ML
13 ML
14 MH
14 MH
15
Command_Data3
H
15
Response_Data3
H
Sub-command: specific to 32 byte mode
Command
Response
Byte bit7
6
5
4
3
2
1
0
Byte
bit7
6
5
4
3
2
1
0
16
Sub_
Chk
(1)
0 0 0
Sub_Command_Code
(0h)
16
Sub_
CMD_
Err
Sub_
ERR
Sub_
WNG
Sub_
Busy
Sub_Command_Code_Ech
o
(0h)
17 Sub_Type_Code
17 Sub_Type_Code_Echo
18 L
18 L
19
Sub_Index
H
19
Sub_Index_Echo
H
20 L
20 L
21 ML
21 ML
22
M
H
22
M
H
23
Sub_Command_Data1
H
23
Sub_Response_Data1
H
24 L
24 L
25 ML
25 ML
26
M
H
26
M
H
27
Sub_Command_Data2
H
27
Sub_Response_Data2
H
28 L
28 L
29 ML
29 ML
30
M
H
30
M
H
31
Sub_Command_Data3
H
31
Sub_Response_Data3
H
Title
Command
Response
Command_Data2
/Response_Data2
Optional
Data specified by Pr.7.30 RTEX monitor select 2
Command_Data3
/ Response_Data3
Data specified by Pr.7.35 (RTEX command setup 1)
▪
For details, refer to Sections 7-7-1.
Data specified by Pr.7.31 RTEX monitor select 3
Sub_Type_Code Optional
–
Sub_Index Optional
–
Sub_Command_Data1
/Sub_Response_Data1
Optional
Data specified by Pr.7.32 (RTEX monitor select 4)
Compatible control mode
NOP
PP
CP
CV
CT