7-6 Control mode switching
7-6-1 Control mode switching method
• When cyclic command change is received, the control mode is changed accordingly.
MINAS-A5N can response to the new control mode changed during operation.
For precautions for mode change during operation, refer to 7-6-2 and for other precautions refer to 7-6-3.
• The non-cyclic command just prior to command mode change must be “Normal command (
0h)”, and be sure to
change the control mode while “Non-cyclic command” is not being executed (Busy = 0). If the control mode is
changed while non-cyclic command is being executed (Busy = 1), Err91.1 (RTEX command error protection) and
command error (002Eh) will occur.
Example: During operation in CV (cyclic velocity control), mode is changed to PP (profile positioning)
Command code
(byte1)
<At master (host controller)>
<Slave>
(byte4-7)
Velocit
y
00002000h
Time
Control mode
Position control
(PP)
Velocity control
(CV)
(byte12-15)
Setting_Data
36h
Parameter command of CV
17h
Normal command of
CV
Normal command of CV
TPOS = 01000000h
CSPD = 00002000h
TSPD = ASPD just before switching
00000000h
30h
Command code
(byte1)
(byte4-7)
(byte8-11)
Type_Code_Echo etc.
36h
17h
Response_Data1 (default APOS)
Response_Data2
(default APOS)
30h
Busy 1 0
Internal
command
velocity
ASPD
Actual
velocity
Stop at TPOS
(byte12-15)
Monitor_Data
Monitor_Data
00000000h
Type_Code_Echo etc.