2-4 Node address (MAC-ID) setting and front panel configuration
The figure below shows the front panel configuration of MINAS-A5N series.
• Set the node address (MAC-ID) in a decimal number: high order digit on MSD rotary switch and low order on LSD
switch.
Example: When MAC-ID is 13, MSD = 1, LSD = 3.
• Node address (MAC-ID) set with the rotary switch will be loaded once when the control power is turned on.
Therefore, a change made after the power up will not be reflected to the control but will become active upon the next
power up.
• Do not change the value of the rotary switch in power on to avoid a trouble.
• Setup range of the node address (MAC-ID) is 0 to 31.
If the setup value exceeds 31, Err 82.0 (COM invalid node-address protection) will be occurred.
• The host controller (master), when transmitting, should specify the node address (MAC-ID) in Byte 0, bits 4-0 of the
command. If the node address is different from the address specified by the servo drive, Err 86.0 (Cyclic data error
protection 1) will occur.
7-segment LED (2-digit)
Connector for analog monitor (X7)
Pin No.
Symbol
Description
1 AM1
Analog
monitor
1
2 AM2
Analog
monitor
2
3 GND
Signal
ground
4, 5, 6
-
Reserved
(Do not connect)
LINK
LED
COM
LED
Rotary switch (RSW) for node
address (MAC-ID) setup
Setup range: 0 to 31