No. SX-DSV02310 - 14 -
R2.0 Motor
Business
Division,
Appliances Company, Panasonic Corporation
3-3 Transmission of Non-Cyclic Data
3-3-1 Non-cyclic transmission area
Use bytes 8 to 15 in Command/Response Data Block and bytes 17 to 23 in 32-byte mode as Non-cyclic transmission
area for event-driven data such as parameter setup.
Main command: common to 16 byte and 32 byte mode
Command
Response
Byte bit7
6
5
4
3
2
1
0
Byte
bit7
6
5
4
3
2
1
0
0
C
(0)
Update_Counter
MAC-ID
0
R
(1)
Update_Counter
_Echo
Actual MAC-ID
1
TMG_
CNT
Command_Code
1
CMD_
Error
Command_Code_Echo
2
2
3
Control_Bits
3
Status_Flags
4
4
5
5
6
6
Cyc
lic
7
Command_Data1
7
Response_Data1
8
8
9
9
10
10
11
Command_Data2
11
Response_Data2
12
12
13
13
14
14
Non-
cyclic
15
Command_Data3
15
Response_Data3
Sub-command: specific to 32 byte mode
Command
Response
Byte bit7
6
5
4
3
2
1
0
Byte
bit7
6
5
4
3
2
1
0
16
Sub_
Chk
0 0 0 Sub_Command_Code 16
Sub_
CMD_
Err
Sub_
ERR
Sub_
WNG
Sub_
Busy
Sub_Command_Code_Echo
17 Sub_Type_Code 17
Sub_Type_Code_Echo
18
18
19
Sub_Index
19
Sub_Index_Echo
20
20
21
21
22
22
Non-cycli
c
23
Sub_Command_Data1
23
Sub_Response_Data1
24
24
25
25
26
26
27
Sub_Command_Data2
27
Sub_Response_Data2
28
28
29
29
30
30
Cyclic
31
Sub_Command_Data3
31
Sub_Response_Data3