No. SX-DSV02310 - 41 -
R2.0 Motor
Business
Division,
Appliances Company, Panasonic Corporation
• CS1, CS2 and CS3 can be allocated to bit3, bit4 and bit5 respectively depending on the set value of Pr7.40.
When allocating CS1, CS2 and CS3, status values of SI-MON1 or EXT1, SI-MON2 or EXT2, or SI-MON3 or EXT3 are not
returned.
But, CS signal are returned with signal before reverse process (original signal) of Pr3.26.
•
CS1, CS2 and CS3 are allocated simultaneously. Only one or two of them can not be allocated.
•
CS_Complete can be allocated to either bit0-7 by the set value of Pr7.43
When CS_Complete is allocated, status value of signal before allocation is not returned.
Class
No.
Title
Unit
Setting Range
Size
[byte]
Function/Description
7 40
RTEX function
Expansion setting 4
-
-32768
–32767
2
bit1: Switch data which set to Byte3.bit3-5 of
RTEX status at CS signal method
(Pr9.20=1).
0: SI-MON1/EXT1-SI-MON3/EXT3
1: CS1–CS3
Class
No.
Title
Unit
Setting Range
Size
[byte]
Function/Description
7 43
Magnetic pole position
estimation
Completion output
setting
-
0–8
2
Set bit arrangement that output t magnetic pole
position estimation completion output
(CS_Complete) to Byte3 of RTEX status.
Setting by this parameter has priority (prior to
Pr7.40-bit1 setting).
0: No allocation bit
1: Byte3.bit0 (NOT/POT)
2: Byte3.bit1 (POT/NOT)
3: Byte3.bit2 (HOME)
4: Byte3.bit3 (SI-MON1/EXT1/CS1)
5: Byte3.bit4 (SI-MON2/EXT2/CS2)
6: Byte3.bit5 (SI-MON3/EXT3/CS3)
7: Byte3.bit6 (SI-MON4/EX-SON)
8: Byte3.bit7 (SI-MON5/E-STOP)
▪
In ( ) is signal name before allocation.