157
DP-8032/8025
2008
Ver. 1.2
406
RCV
(Password
Comm.)
B
XMT-Password mismatched. RCV-
Password mismatched. Selective
RCV incomplete.
XMT, RCV password does not match.
Last 4 digits of TSI does not match with
the last 4 digits of Auto Dial telephone
number.
407
XMT
D
Transmitter received no response
after it transmitted post message,
such as EOP, MPS, EOM, etc...or
received DCN.
Receiver defective. (No paper, paper
jamming, etc.)
Receiver ceased receiving because of
excessive errors. (Line quality poor)
FXB PCB (Modem) or MJR PCB
defective.
408
XMT
D
Transmitter received RTN after it
transmitted EOP, MPS, or EOM.
Receiver receives data with errors.
(Line quality poor)
Receiver defective. (Modem, MJR
PCB, etc.)
FXB PCB or MJR PCB defective.
409
XMT
D
Transmitter receives PIN after it
transmitted a post message, such
as EOP, MPS, EOM, etc.
Receiver receives data with error due
to poor line quality, and receiving
operator requests voice contact.
Receiver defective. (Modem, MJR
PCB, etc.)
FXB PCB or MJR PCB defective.
410
RCV
D
Received DCN while waiting for
post command. (EOP, MPS, EOM,
etc.)
Interface or line faulty.
Transmitter defective.
411
RCV
(Polling)
B
Received DCN after transmitting
NSC.
Transmitter not ready for polling
communication.
Password does not match between
transmitter and receiver.
412
G3 RX
B, D
No response within 12 seconds in
NSS/DCS/MPS wait state. (After
transmitting FTT)
Transmitter defective.
FXB PCB defective.
414
RCV
(Polling)
B
No response received after
transmitting 3rd NSC.
Password does not match between
transmitter and receiver.
Transmitter defective. (No original,
document jam, etc.)
415
XMT
(Polling)
B
Remote side attempted to receive
message from your machine in
polling communication.
Inform the remote side that your
machine does not have the polling
transmission feature.
416
RCV
D
Receiver did not detect post
command, such as EOP, MPS,
EOM, etc.
Transmitter defective.
Line quality poor. (RTC signal distorted
due to line noise)
FXB PCB or MJR PCB defective.
417
RCV
C
Receiver returned RTN in
response to post message.
Line quality poor. (There are excessive
errors in received data)
FXB PCB or MJR PCB defective.
418
RCV
C
Receiver transmitted PIN in
response to PRI-Q from
transmitter. (Transmitting operator
requests voice contact)
Line quality poor. (There are excessive
errors in received data)
FXB PCB or MJR PCB defective.
420
RCV
B
T1 timer (35 sec.) elapsed without
detecting 300 bps signal.
Wrong number dialed.
(Non-facsimile communication)
Transmitter defective.
FXB PCB or MJR PCB defective.
Fax Information Codes
Code
Mode
Phase
Description of Problem
Possible Cause(s)
Summary of Contents for DP-8032