4.3.15. Document Skewing
4.3.15.1. LSU Skew Adjustment
(1) Open the Front Cover and the Right Cover.
(2) Slide the Process Unit out. (Refer to 2.2.4.)
Caution:
Exercise caution not to scratch the surface of the
OPC Drum
(Green), and not to touch it with bare
hands.
(3) Remove the Front Left Cover. (Refer to 2.2.10.)
(4) Loosen 4 Red Screws.
Adjust the Lever Plate downwards and recheck the
Document Skewing. Readjust as needed.
One scale adjusts the skewed image by approximately
0.01 mm.
Adjust the Lever Plate upwards and recheck the
Document Skewing. Readjust as needed.
END
START
Is the LSU normal?
Check the Scanner
or ADF/iADF mechanism.
Check or replace LSU.
No
No
Yes
Yes
Is the Test Pattern printout
in Copier F1 Mode normal?
Copy Mode
Sample
Document Leading Edge
< Example of Printed Image >
A
Document Leading Edge
< Example of Printed Image >
A