INF-51
H00: OTHER ADJUST
Item Set
value
No.
SUPER
DISP.
No.
SUPER
DISP.
Setting contents and
outline function explanation
BACK
-UP
Remarks
H01 STILL LIMIT
0
1
2 min
6 min
Set the maximum value of the "SETUP-MENU 400 : STILL TIMER".
Decide whether the still timer should be reset when the
STANDBY-ON command is received during the STOP mode.
0:2 min/The still timer should not be reset
1:6 min/The still timer should be reset
Yes
H02 LTC OUT SEL
0
1
N-STOP
STOP
Selection of TC output according to the mode or not
0: Output always, independent of the mode
1: ON/OFF switching of the TC output according to the VTR mode.
However, the TC output always is ON at the time of SETUP
MENU 317: AUD MEM MODE = AMU_X, AMU_VO.
Yes
H02: TC output in case of LTC OUT SEL = STOP setting
TC
INT/EXT
Mode
VV / EE
TC output
EJECT
STOP
STANDBY OFF
JOG/VAR/SHTL STILL
— OFF
INT
Others —
ON
V V
(including BLACK, GLAY of EJECT)
OFF
EJECT
STOP
STANDBY OFF
JOG/VAR/SHTL STILL
EE ON
EXT
Others
—
ON