MECH-35
Adjust within specification
Sens. Value : 101.58mV/um
Sens. 1 : 104.72mV/um
Sens. 2 : 98.44mV/um
3-37. PB Head LISTA Sensitivity Adjustment and Sensitivity Detection
(50M Mode)
SPEC.
Sensitivity 100±10 (mV/
µ
m)
MODE
SERVO Adjustment Menu “A17 : PBL GAIN 25”
!
ATF (PB-L)
TP6701 RF/CUE
"
H SW (PB-L)
TP232 SERVO (F1)
TEST POINT
#
GND
TG6001 RF/CUE
ADJUSTMENT
SERVO Adjustment Menu: “A16 : PBL GAIN 50”
TAPE
NTSC: VFM3581KM or VFM3581KL(LISTA)
(PAL: VFM3681KM or VFM3681KL(LISTA))
1. Open the Service Menu and select “A16: PBL GAIN 50” in the “SERVO ADJUST” menu. Set the Lista software
in 50M mode.
2. Playback a LISTA alignment tape (VFM3581KM or VFM3581KL).
3. Select the LISTA Main Menu “(6) ATF Error Signal Monitor” so that the screen of <ATF Error Signal monitor>
appears. Then press Enter to start the software.
4. When the picture is appeared as shown in figure 3-37-1, adjust ATF Gain (A16: PBL GAIN 50) so that the “Sens.
Value:” is in the Specification.
5. After finishing the Adjustment, press ESC key to return the main menu.
6. Select the Lista Main Menu “(1) Sensitivity Measurement” so that the screen of <ATF Error Signal monitor>
appears.
7. Playback a Lista alignment tape and press “ENTER” to start the Sensitivity measurement.
8. Confirm that the sensitivity value is within the specification. (refer to figure 3-37-2).
9. If it is out of specification, return to item 3.
Figure 3-37-1
Summary of Contents for AJ-D93MC
Page 3: ... 3 ...
Page 4: ... 4 AJ D93MC ...
Page 5: ... 5 ...
Page 6: ... 6 AJ YA93P AJ YA94G ...
Page 8: ... 8 AJ SD93P E ...
Page 9: ... 9 ...
Page 10: ... 10 ...
Page 11: ... 11 AJ YA93P AJ YA94G ...
Page 12: ...FCD0409NTKK145E466E467 ...
Page 65: ...INF 52 14 ERROR MESSAGES ...
Page 66: ...INF 53 ...
Page 67: ...INF 54 ...
Page 68: ...INF 55 ...
Page 110: ...MECH 32 Figure 3 35 2 Confirm this value ...