INF-47
Item Set
value
No.
SUPER
DISP.
No.
SUPER
DISP.
Setting contents and
outline function explanation
BACK
-UP
Remarks
P30
Q30
R30
T L1 2A
-31
|
0
|
40
-31
|
0
|
40
Yes Use for electrical adjustment
P31
Q31
R31
T L1 1A
-88
|
-32
|
-4
-88
|
-32
|
-4
• Read-out is possible only at the time of PLAY, REC.
Operation:
• At the time of P53, Q53: IC READ = SINGLE
Read-out and display are performed each time the SET
button is pressed.
• At the time of P53, Q53: IC READ = CONT
Read-out and display are performed once every second.
Yes Use for electrical adjustment
P32
Q32
R32
T L1 1B
-88
|
-32
|
-4
-88
|
-32
|
-4
Yes Use for electrical adjustment
P33
Q33
R33
T L1 2B
-31
|
0
|
40
-31
|
0
|
40
Yes Use for electrical adjustment
P34
Q34
R34
T L1 3B
-31
|
0
|
31
-31
|
0
|
31
The initial values for six of the seven tap coefficients of the adaptive
equalization filter, excluding the fixed center tap, are set for the L1
head. The tap coefficient values after adaptive equalization filter
convergence at the time of standard tape playback are read out and
set.
• Read-out is possible only at the time of PLAY, REC.
Operation:
• At the time of P53, Q53: IC READ = SINGLE
Read-out and display are performed each time the SET
button is pressed.
• At the time of P53, Q53: IC READ = CONT
Read-out and display are performed once every second.
Yes Use for electrical adjustment
P35
Q35
R35
T L2 3A
-31
|
0
|
31
-31
|
0
|
31
Yes Use for electrical adjustment
P36
Q36
R36
T L2 2A
-31
|
0
|
40
-31
|
0
|
40
Yes Use for electrical adjustment
P37
Q37
R37
T L2 1A
-88
|
-32
|
-4
-88
|
-32
|
-4
Yes Use for electrical adjustment
P38
Q38
R38
T L2 1B
-88
|
-32
|
-4
-88
|
-32
|
-4
Yes Use for electrical adjustment
P39
Q39
R39
T L2 2B
-40
|
0
|
31
-40
|
0
|
31
Yes Use for electrical adjustment
P40
Q40
R40
T L2 3B
-31
|
0
|
31
-31
|
0
|
31
The initial values for six of the seven tap coefficients of the adaptive
equalization filter, excluding the fixed center tap, are set for the L2
head. The tap coefficient values after adaptive equalization filter
convergence at the time of standard tape playback are read out and
set.
• Read-out is possible only at the time of PLAY, REC.
Operation:
• At the time of P53, Q53: IC READ = SINGLE
Read-out and display are performed each time the SET
button is pressed.
• At the time of P53, Q53: IC READ = CONT
Read-out and display are performed once every second.
Yes Use for electrical adjustment
P41
Q41
R41
T R1 3A
-31
|
0
|
31
-31
|
0
|
31
Yes Use for electrical adjustment
P42
Q42
R42
T R1 2A
-31
|
0
|
40
-31
|
0
|
40
Yes Use for electrical adjustment
P43
Q43
R43
T R1 1A
-88
|
-32
|
-4
-88
|
-32
|
-4
The initial values for six of the seven tap coefficients of the adaptive
equalization filter, excluding the fixed center tap, are set for the R1
head. The tap coefficient values after adaptive equalization filter
convergence at the time of standard tape playback are read out and
set.
• Read-out is possible only at the time of PLAY, REC.
Operation:
• At the time of P53, Q53: IC READ = SINGLE
Read-out and display are performed each time the SET
button is pressed.
• At the time of P53, Q53: IC READ = CONT
Read-out and display are performed once every second.
Yes Use for electrical adjustment
Summary of Contents for AJ-D93MC
Page 3: ... 3 ...
Page 4: ... 4 AJ D93MC ...
Page 5: ... 5 ...
Page 6: ... 6 AJ YA93P AJ YA94G ...
Page 8: ... 8 AJ SD93P E ...
Page 9: ... 9 ...
Page 10: ... 10 ...
Page 11: ... 11 AJ YA93P AJ YA94G ...
Page 12: ...FCD0409NTKK145E466E467 ...
Page 65: ...INF 52 14 ERROR MESSAGES ...
Page 66: ...INF 53 ...
Page 67: ...INF 54 ...
Page 68: ...INF 55 ...
Page 110: ...MECH 32 Figure 3 35 2 Confirm this value ...