ELE-5
3. AVMON BOARD (F2)
<1> TP/VC Location
3-1. PLL
DC Adjustment
BOARD
AVMON (F2)
TP
TP300
ADJ.
VC300
INPUT
-----
MODE
EE
TAPE
-----
M. EQ
Oscilloscope
SPEC.
0VDC ± 0.1VDC
<Service Menu>
F00 VIDEO AJUST, F18 --- DIF PLL TEST : ON
1. Open the Service Menu and select the above.
2. Adjust VC300 so that the DC voltage is in the
specification.
TP300 VC300
Summary of Contents for AJ-D93MC