INF-45
RP ADJUST (DVCPRO 50M ADJUST, DVCPRO 25M ADJUST, DV ADJUST sub-screen)
Item Set
value
No.
SUPER
DISP.
No.
SUPER
DISP.
Setting contents and
outline function explanation
BACK
-UP
Remarks
P01
Q01
R01
AGC LEV L1
-128
|
-20
|
127
-128
|
-20
|
127
Adjustment of the L1 head playback phase
Yes Use for electrical adjustment
P02
Q02
R02
AGC LEV L2
-128
|
-20
|
127
-128
|
-20
|
127
Adjustment of the L2 head playback phase
Yes Use for electrical adjustment
P03
Q03
R03
ATF MAG L1
-128
|
20
|
127
-128
|
20
|
127
Adjustment of the L1 head playback amplitude
Yes Use for electrical adjustment
P04
Q04
R04
ATF MAG L2
-128
|
20
|
127
-128
|
20
|
127
Adjustment of the L2 head playback amplitude
Yes Use for electrical adjustment
P05
Q05
R05
AGC LEV R1
-128
|
-20
|
127
-128
|
-20
|
127
Adjustment of the R1 head playback phase
Yes Use for electrical adjustment
P06
Q06
R06
AGC LEV R2
-128
|
-20
|
127
-128
|
-20
|
127
Adjustment of the R2 head playback phase
Yes Use for electrical adjustment
P07
Q07
R07
MAG R1
-128
|
20
|
127
-128
|
20
|
127
Adjustment of the R1 head playback amplitude
Yes Use for electrical adjustment
P08
Q08
R08
MAG R2
-128
|
20
|
127
-128
|
20
|
127
Adjustment of the R2 head playback amplitude
Yes Use for electrical adjustment
P09
Q09
R09
ENV L1
0
|
255
0
|
255
Yes
Factory use only
P10
Q10
R10
ENV L2
0
|
255
0
|
255
Yes
Factory use only
P11
Q11
R11
ENV R1
0
|
255
0
|
255
Yes
Factory use only
P12
Q12
R12
ENV R2
0
|
255
0
|
255
Playback signal envelope level read-out value averaged for each
track of each head
ENV L1: L1 head
ENV L2: L2 head
Averaging is performed at 8 points in the track, and the newest track
value for which averaging has been completed at the time when
read-out is started will be read out.
• Read-out is possible only at the time of PLAY and REC.
Yes
Factory use only
P13
Q13
R13
AGC SPD
0
|
3
0
|
3
Setting of the AGC response speed
Yes
Factory use only
Do not change any setting
P14
Q14
R14
AEQ SPD
0
1
2
3
0
1
2
3
The control response speed for the adaptive equalization filter is set
in four levels.
The sensitivity is highest with 0 and lowest with 3.
Yes
Factory use only
Do not change any setting
P15
Q15
R15
HLD SEN
0
1
2
3
0
1
2
3
The detection sensitivity for detection of changes in the relative
speed is set in four levels.
The sensitivity is highest with 0 and lowest with 3.
Yes
Factory use only
Do not change any setting
Summary of Contents for AJ-D93MC
Page 3: ... 3 ...
Page 4: ... 4 AJ D93MC ...
Page 5: ... 5 ...
Page 6: ... 6 AJ YA93P AJ YA94G ...
Page 8: ... 8 AJ SD93P E ...
Page 9: ... 9 ...
Page 10: ... 10 ...
Page 11: ... 11 AJ YA93P AJ YA94G ...
Page 12: ...FCD0409NTKK145E466E467 ...
Page 65: ...INF 52 14 ERROR MESSAGES ...
Page 66: ...INF 53 ...
Page 67: ...INF 54 ...
Page 68: ...INF 55 ...
Page 110: ...MECH 32 Figure 3 35 2 Confirm this value ...