INF-16
<< Hours Meter Reset Procedure >>
1.
Press
the
“EJECT”
+
“STOP”
and
“PF”
+
“MENU”
buttons on the Front Panel simultaneously so that
the display shows the
“HOURS METER”
as shown below.
2. Then move the cursor
(*)
to the item with
“r”
to be reset.
3.
Press
the
“RESET”
button on the Front Panel so that the display changes as shown below. After the
following confirmation message is displayed, move the cursor
(*)
to the item to reset by controlling the
Joy Stick. (Only H11 – H14 with
“ r ”
can be reset.)
4. When confirming the message
“* * * * * *r OK?”,
press the
“PLAY”
button on the Front Panel, the data
(***H) for the item where the cursor is located will be reset.
5.
Press
the
“MENU”
button simultaneously press the
“PF”
button so that the VTR returns to the normal
screen.
DIAG-MENU HOURS
METER
Ser 0000000001
H00 OPERATION 1000H
H01 DRUM RUN
2000H
H02 TAPE RUN
3000H
H03 THREADING 4000T
H04 F LOADING
4000T
* H11 DRUM RUN r 2000H
H12 TAPE RUN r
3000H
H13 THREADING r 4000T
H14 F LOADING r 4000T
END
HOURS METER INIT SET
DRUM RUN r OK?
YES<PLAY >/NO<STOP>
Summary of Contents for AJ-D93MC
Page 3: ... 3 ...
Page 4: ... 4 AJ D93MC ...
Page 5: ... 5 ...
Page 6: ... 6 AJ YA93P AJ YA94G ...
Page 8: ... 8 AJ SD93P E ...
Page 9: ... 9 ...
Page 10: ... 10 ...
Page 11: ... 11 AJ YA93P AJ YA94G ...
Page 12: ...FCD0409NTKK145E466E467 ...
Page 65: ...INF 52 14 ERROR MESSAGES ...
Page 66: ...INF 53 ...
Page 67: ...INF 54 ...
Page 68: ...INF 55 ...
Page 110: ...MECH 32 Figure 3 35 2 Confirm this value ...