MECH-37
3-38. RP HEAD (for DV) Lista Sensitivity Adjustment
SPEC.
Sensitivity: 130±30 (mV/
µ
m)
VTR MODE
PLAYBACK
!
ATF (R/P-R)
TP6801 RF/CUE
"
H SW (R/P-R)
TP235 SERVO (F1)
TEST POINT
#
GND
TG6001 RF/CUE
ADJUSTMENT
SERVO Adjustment Menu: “A18: RPR GAIN DV”
TAPE
VFM3000EDS
1. Set the LISTA software in 50M Mode. 25M and 50M mode can be changed by “0” key on the key board.
2. Select the item “A18: RPR GAIN DV” in the “SERVO ADJUST” menu.
3. Playback a DV LISTA alignment tape (VFM3000EDS).
4. Select the LISTA (6) ATF Error Signal Monitor so that the screen of <ATF Error Signal monitor> appears. (refer
to figure 3-38-2) Then press Enter to start the software.
In case “ATF Error Signal Monitor”
or “sensitivity Measurement” is selected.
Select for sensitivity detection
Select for Linearity adjustment
Select for sensitivity
adjustment
Figure 3-38-1
Figure 3-38-2
Summary of Contents for AJ-D93MC