88
Chapter 6 - Parts Removal and Replacement
Access Plates
Each of the DLT LibraryXpress modules has a single cover plate which, when removed,
provides access to all internal components.
Removal
Refer to Figure 6-3.
1.
Loosen the captive screws at the left and right of the front panel to permit the
module to be pulled from the rack.
2.
Disconnect all power and interface cables at the rear of the module.
3.
Pull the module out of the rack on its slides, until both slides lock in the extended
position.
4.
Note: This step should be performed by two people, one on each side of the module.
Refer to the lower picture in Figure 2-11. Press inward on the inner slide lock on
each side while pulling the module completely out of the rack. Place the module on a
suitable work surface.
5.
Unscrew the captive screw near the center of the cover plate.
6.
Slide the cover plate one-half inch toward the rear.
7.
Lift the cover plate clear of the module.
Summary of Contents for DLT LibraryXpress Series